Figure 122. ServeRAID SAS/SATA controller signal cable connection for hot-swap hard disk
drive models (left PCI module connection with two backplanes)
3. Make sure the relevant cables pass through the cable clips.
4. Align the ServeRAID SAS/SATA controller so that the keys align correctly with
5. Insert the ServeRAID SAS/SATA controller into the connector on the PCI
6. Reinstall the PCI riser-card assembly (see "Replacing the PCI riser-card
7. Reinstall the cover (see "Replacing the cover" on page 81).
What to do next
1. Install the server into the rack enclosure and push the server into the rack until
2. Reconnect the power cords and any cables that you removed.
3. Turn on the peripheral devices and the server.
Note: When you restart the server, you are prompted to import the existing RAID
configuration to the new ServeRAID SAS/SATA controller.
202
System x3250 M5 Type 5458: Installation and Service Guide
the connector on the PCI riser-card assembly.
riser-card assembly until it is firmly seated.
Attention: Incomplete insertion might cause damage to the server or the
ServeRAID SAS/SATA controller.
assembly" on page 79).
it clicks into place.