4000008a-00000000 • 80010202-0701ffff
CIM Information: Prefix: IMM and ID: 0137
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Turn off the server and disconnect it from the
power source. You must disconnect the server from
ac power to reset the IMM.
2. After 45 seconds, reconnect the server to the power
source and turn on the server.
3.
Retry the operation.
4000008a-00000000
Management Controller [arg1]:
Configuration restoration from a file by
user [arg2] failed to start.
Explanation: This message is for the use case where a
user restores a Management Controller configuration
from a file and the restoration fails to start.
May also be shown as 4000008a00000000 or
0x4000008a00000000
Severity: Error
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: IMM and ID: 0138
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Turn off the server and disconnect it from the
power source. You must disconnect the server from
ac power to reset the IMM.
2. After 45 seconds, reconnect the server to the power
source and turn on the server.
3.
Retry the operation.
4000008b-00000000
One or more of the Storage
Management IP addresses has changed.
Explanation: This message is for the use case where
an IP address for the Storage Management has changed
May also be shown as 4000008b00000000 or
0x4000008b00000000
Severity: Info
Alert Category: System - IMM Network event
Serviceable: No
CIM Information: Prefix: IMM and ID: 0139
SNMP Trap ID: 37
Automatically notify Support: No
User response: Information only; no action is
required.
326
System x3250 M5 Type 5458: Installation and Service Guide
80010002-0701ffff
Numeric sensor
[NumericSensorElementName] going
low (lower non-critical) has asserted.
(CMOS Battery)
Explanation: This message is for the use case when an
implementation has detected a Lower Non-critical
sensor going low has asserted.
May also be shown as 800100020701ffff or
0x800100020701ffff
Severity: Warning
Alert Category: Warning - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0476
SNMP Trap ID: 13
Automatically notify Support: No
User response: Replace the system battery.
80010202-0701ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted.
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has asserted.
May also be shown as 800102020701ffff or
0x800102020701ffff
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 1
Automatically notify Support: Yes
User response: If the specified sensor is CMOS
battery, replace the system battery. If the specified
sensor is Planar 3.3V or Planar 5V, (trained technician
only) replace the system board. If the specified sensor
is Planar 12V, complete the following steps until the
problem is solved:
Check power supply n LED.
1.
2.
Remove the failing power supply.
3.
Follow actions for OVER SPEC LED in Light path
diagnostics LEDs.
4.
(Trained technician only) Replace the system board.
(n = power supply number)