Lenovo 5458 Installation And Service Manual page 375

Table of Contents

Advertisement

May also be shown as 806f050d0406ffff or
0x806f050d0406ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0407ffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 7)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0407ffff or
0x806f050d0407ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
Make sure that the RAID adapter firmware and
1.
hard disk drive firmware are at the latest level.
Make sure that the SAS cable is connected
2.
correctly.
Replace the SAS cable.
3.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f0513-2582ffff
A PCI SERR has occurred on
system [ComputerSystemElementName].
(PCIs)
Explanation: This message is for the use case when an
806f050d-0407ffff • 806f052b-2101ffff
implementation has detected a PCI SERR.
May also be shown as 806f05132582ffff or
0x806f05132582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0234
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check the PCI LED.
2.
Reseat the affected adapters and riser card.
Update the server firmware (UEFI and IMM) and
3.
adapter firmware. Important: Some cluster solutions
require specific code levels or coordinated code
updates. If the device is part of a cluster solution,
verify that the latest level of code is supported for
the cluster solution before you update the code.
4.
Make sure that the adapter is supported. For a list
of supported optional devices, see
http://www.ibm.com/systems/info/x86servers/
serverproven/compat/us/.
5.
Remove both adapters.
6.
Replace the PCIe adapters.
7.
Replace the riser card.
806f052b-2101ffff
Explanation: This message is for the use case when an
implementation has detected an Invalid/Unsupported
Firmware/Software Version.
May also be shown as 806f052b2101ffff or
0x806f052b2101ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0446
SNMP Trap ID: 50
Automatically notify Support: No
User response:
Make sure the server meets the minimum
1.
configuration to start (see Power-supply LEDs).
Recover the server firmware from the backup page
2.
by restarting the server.
Update the server firmware to the latest level (see
3.
Updating the firmware). Important: Some cluster
solutions require specific code levels or coordinated
Appendix A. Integrated Management Module II (IMM2) error messages
Invalid or Unsupported firmware
or software was detected on system
[ComputerSystemElementName]. (IMM2
FW Failover)