Lenovo 5458 Installation And Service Manual page 378

Table of Contents

Advertisement

806f060d-0407ffff • 806f070c-2004ffff
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
Replace the hard disk drive that is indicated by a
5.
lit status LED.
806f060d-0407ffff
Array
[ComputerSystemElementName] has
failed. (Drive 7)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0407ffff or
0x806f060d0407ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f070c-2001ffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 1)
Explanation: This message is for the use case when an
implementation has detected a Memory DIMM
configuration error has been corrected.
May also be shown as 806f070c2001ffff or
0x806f070c2001ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed in
362
System x3250 M5 Type 5458: Installation and Service Guide
the correct sequence and have the same size, type,
speed, and technology.
806f070c-2002ffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 2)
Explanation: This message is for the use case when an
implementation has detected a Memory DIMM
configuration error has been corrected.
May also be shown as 806f070c2002ffff or
0x806f070c2002ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed in
the correct sequence and have the same size, type,
speed, and technology.
806f070c-2003ffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 3)
Explanation: This message is for the use case when an
implementation has detected a Memory DIMM
configuration error has been corrected.
May also be shown as 806f070c2003ffff or
0x806f070c2003ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed in
the correct sequence and have the same size, type,
speed, and technology.
806f070c-2004ffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 4)
Explanation: This message is for the use case when an
implementation has detected a Memory DIMM
configuration error has been corrected.

Advertisement