Procedure
1. Install the adapter in the PCI riser-card assembly (see "Replacing an adapter"
on page 194 or "Replacing an Lenovo ServeRAID SAS/SATA controller" on
page 197).
2. Reconnect any adapter cables that you disconnected when you removed the
PCI riser-card assembly.
3. Carefully align the PCI riser-card assembly with the guides on the rear of the
server and with the PCI riser-card connector on the system board; then, place
your thumbs on locations marked by the blue tabs and press down on the PCI
riser-card assembly. Make sure that the riser-card assembly is fully seated in the
connector on the system board.
Figure 92. PCI riser-card assembly installation
4. Reinstall the cover (see "Replacing the cover" on page 81).
What to do next
1. Install the server into the rack enclosure and push the server into the rack until
it clicks into place.
2. Reconnect the power cords and any cables that you removed.
3. Turn on the peripheral devices and the server.
Removing the RAID adapter battery or flash power module
holder
Use this information to replace the RAID adapter battery or flash power module
holder in the server.
Before you begin
Note: RAID adapter battery or flash power module holder is only supported in
the 2.5-inch models.
Chapter 6. Removing and replacing server components