Fuel level (FL)
Speed (SPD)
Voltage of Battery (VB)
Voltage of Charger (VD)
Hour counter (HC)
Start times
─ Control and protection function: realize automatic start/stop of the diesel gen-set, breaker close and
open (ATS transfer) control and perfect fault indication protection function.
─ All output ports are relay outputs;
─ Parameter setting function: parameters can be modified by users and stored in internal FLASH
memory and cannot be lost even in case of power outage; most of them can be adjusted by using
front panel of the controller and all of them can be modified by using PC via USB port, RS485, RS232
or ETHERNET ports.
─ Multiple curves of temperature, oil pressure, and fuel level sensors can be used directly and users
can define the sensor curves by themselves.
─ Multiple crank disconnect conditions (speed sensor, oil pressure, generator frequency) are optional.
─ Wide power supply range DC(8~35)V, suitable for different starting battery voltage environment;
─ Event log, real-time clock, scheduled start & stop generator functions (can be set to start genset once
a day/week/month with load or not).
─ PLC (Programmable Logic Controller) function. Users can use graphical programming to achieve
specific functions.
─ Can be used as an indicating instrument (only for indication and alarm, no action for relay).
─ Maintenance function. Actions (warning, shutdown or trip and stop) can be set when maintenance
time is out.
─ All parameters are digitally adjusted, getting rid of conventional analog modulation with normal
potentiometer, improving whole case's reliability and stability;
─ Ingress Protection level IP65 due to rubber gasket installed between the controller enclosure and
control window;
─ Metal fixing clips are used to fix controller, outstanding performance in high temperature environment;
─ Modular design, pluggable connection terminals and embedded installation way; compact structure
with easy mounting.
Accumulative running A and B, accumulative electric power A and B; users can zero clear them and
accumulate them again, making convenience for users.
HGM8110DC-2 Genset Controller
HGM8110DC-2 GENSET CONTROLLER USER MANUAL
%(unit)
r/min (unit)
V (unit)
V (unit)
accumulative to max. 65535 hours.