No.
Type
14
AC Reverse Power
15
AC Over Power
16
ECU Warn
17
AC Loss of Phase
AC Phase Sequence
18
Wrong
19
Switch Fail
20
DC Over Voltage
21
DC Under Voltage
22
DC Over Current
23
DC Over Power
24
Temp. Sensor Open
25
High Temp. Warn
Oil Pressure Sensor
26
Open
27
Low OP Warn
HGM8110DC-2 Genset Controller
HGM8110DC-2 GENSET CONTROLLER USER MANUAL
Action Range
time is due
Active always
Active always
Active when ECU receives
yellow indicator alarm
Detected
when
Phase
voltage>30V,
voltage>50V
Detected
when
Phase
voltage>30V,
voltage>50V
Active when breaker close
failed
Active Always
Active from wait for load to
stop cooling
Active Always
Active Always
Active Always
Active from start idle to
stop idle
Active Always
Active from start idle to When controller detects the oil pressure is
2020-02-20
select ―Warn‖, it will send warn signals.
When controller detects the reverse power
value (power is negative) is higher than the
set value and the action select ―Warn‖, it will
send warn signals.
When controller detects the reverse power
value (power is positive) is higher than the
set value and the action select ―Warn‖, it will
send warn signals.
When controller gets the alarm signals from
engine via J1939, it will send warn signals.
When controller detects the AC generator
Line
loss phase, it will send warn signals.
When controller detects the AC generator
Line
phase rotation, it will send warn signals.
When controller detects the switch on and off
fail, and the action select enable, it will send
warn signals.
When controller detects the voltage of DC
genset is higher than the set value, it will
send warn signals.
When controller detects the voltage of DC
genset is lower than the set value, it will
send warn signals.
When controller detects the current of DC
genset is higher than the set value and the
action select ―Warn‖, it will send warn
signals.
When controller detects the reverse power
value (power is positive) is higher than the
set value and the action select ―Warn‖, it will
send warn signals.
When controller detects the sensor is open
circuit, and the action select ―warn‖, it will
send warn signals.
When controller detects the temperature is
higher than the set value, it will send warn
signals.
When controller detects sensor open and
open action selects Warn, it will send
warning signal.
Version 1.0