CPI CLS Advance Operator's Manual page 57

Coin recycler
Table of Contents

Advertisement

CLS Advance
Error code
Description/Cause
Coin was rejected as validator
0xC09F
misses coin to be rejected
Accepted coin has not reached
0xC0A0
hopper yet
Coin was rejected due to
measurement timeout
If reported continuously, coin
0xC0C0
validator arm seems to be in
wrong position
Coin was rejected due to
0xC0C1
measurement lever failure
Coin was rejected due to
0xC0C2
unknown shape
Coin was rejected due to
0xC0C3
unknown trigger
Coin was rejected due to
0xC0C4
oversized shape
Coin was rejected due to under-
0xC0C5
sized shape
Coins were rejected as they
0xC0C6
had lain one upon the other and
thus could not be detected
Coin was rejected due to wrong
0xC0C7
diameter and measurement
timing
Coin/foreign object detected but
0xC0C8
rejected (not programmed)
Communication error between
0xFCnn
coin validator and main PCB
For internal diagnostics only
0xFE00–0F
Configuration data block upload
0xFEF0
successful
Configuration data block upload
0xFEF1
not successful
Coins (accepted) lay close
0xFEF2
together in measurement field
Coins (detected but not pro-
0xFEF3
grammed) lay close together in
measurement field
OM_CLS_-_EN_2-0
Category
Remedy/hints
By whom
Info
• Insert coin again
• Customer
• Cleaning, contact service
• Service
Info
Info
• Insert coin again
• Customer
• Open lid
• Attendant possessing
(cf. Chap. "7.2
Opening and closing the CLS
the key for the upper
and bring coin
lid", p. 48)
lock
validator arm into correct
position
Info
Insert coin again
Customer
Info
Insert coin again
Customer
Info
Insert coin again
Customer
Info
Insert coin again
Customer
Info
Insert coin again
Customer
Info
Insert coins again
Customer
Info
Insert coin again
Customer
Info
Critical
Connection failure, contact
Service
service
Info
Info
Critical
Configuration failure, contact
Service
service
Info
Info
Error code
Description/Cause
Coin counters corrected follow-
0xFEF9
ing an unwanted reset
Unintended reset during opera-
0xFEFA
tion due to ESD for instance
All accepted coins sorted
0xFEFB
Sensor detected unknown
0xFEFC
object and no coin
10.2.2.3
Error codes transmitted by the CLS coin hoppers
Error code
Description/Cause
Hopper sensor covered during
0x02yF
start-up due to coin jam at the
y = 1..8 =
hopper output
Hopper no.
Coin eject timeout. Hopper
0x03yF
found no coin as hopper is
y = 1..8 =
empty
Hopper no.
Hopper sensor covered due to
0x08yF
coin jam at the hopper output
y = 1..8 =
Hopper no.
Hopper overcurrent due to coin
0x0AyF
jam
y = 1..8 =
Hopper no.
Troubleshooting
Category
Remedy/hints
By whom
Info
Info
Info
Info
Category
Remedy/hints
By whom
Critical
Open payout unit and elimi-
Attendant possessing
nate coin jam
the key for the lower
(cf. Chap. "8.5.2
Eliminating hopper coin jam",
lock
p. 39)
Attention
Open payout unit and check
Attendant possessing
if hopper is empty. If so refill
the key for the lower
hopper
lock
(cf. Chap. "8.1 Filling the
.
coin hoppers", p. 31)
Critical
Open payout unit and elimi-
Attendant possessing
nate coin jam
the key for the lower
(cf. Chap. "8.5.2
Eliminating hopper coin jam",
lock
p. 39)
Critical
Open payout unit and elimi-
Attendant possessing
nate coin jam
the key for the lower
(cf. Chap. "8.5.2
Eliminating hopper coin jam",
lock
p. 39)
57