CPI CLS Advance Operator's Manual page 56

Coin recycler
Table of Contents

Advertisement

Troubleshooting
Error code
Description/Cause
Coin not accepted as normal
0x8y83
coin acceptance band inhibited
y = 0..F
by control software (security
= Coin
level (narrow acceptance band)
Type 0–15
activated)
0x8y90
Hardware error during coin
y = 0..F
acceptance
= Coin
Type 0–15
0x8y91
Coin could not be accepted and
y = 0..F
was rejected as at least two
= Coin
coins entered the measurement
Type 0–15
area at the same time
0x8y93
Coin could not be accepted due
y = 0..F
to polling timeout
= Coin
Type 0–15
0x8y94
Coin was rejected as coin ac-
y = 0..F
ceptance was not polled
= Coin
Type 0–15
Coin was rejected as coin posi-
0x8y96
tion sensors covered
y = 0..F
= Coin
Type 0–15
0x8y99
Coin was rejected as event
y = 0..F
buffer is full
= Coin
Type 0–15
0x8y9B
Coin was rejected as previous
y = 0..F
coin has not been accepted yet
= Coin
Type 0–15
0x8y9C
Coin was rejected as previous
y = 0..F
coin has not been rejected yet
= Coin
Type 0–15
0x8y9E
Coin was rejected as validator
y = 0..F
misses coin to be accepted
= Coin
Type 0–15
0x8y9F
Coin was rejected as validator
y = 0..F
misses coin to be rejected
= Coin
Type 0–15
56
Category
Remedy/hints
By whom
Info
If unintended, configuration
Service
failure, contact service
Info
Info
Insert coin(s) again
Customer
Info
If info comes up repeatedly,
Service
configuration failure, contact
service
Info
If info comes up repeatedly,
Service
configuration failure, contact
service
Attention
• Eliminate jam/foreign
• Attendant possessing
object
the key for the upper/
(cf. Chap. "8.5.1 Elimi-
nating coin jam in acceptance
lower lock
unit", p. 38)
• Cleaning, contact service
• Service
Info
Info
Insert coin again
Customer
Info
Insert coin again
Customer
Info
• Insert coin again
• Customer
• Cleaning, contact service
• Service
Info
• Insert coin again
• Customer
• Cleaning, contact service
• Service
Error code
Description/Cause
Category
0x8yA0
Accepted coin has not reached
Info
y = 0..F
hopper yet
= Coin
Type 0–15
0x9yzz
Number of coins accepted
Info
y = 0..F
but not sorted correctly (only
= Coin
transmitted if not equal to coins
Type 0–15
sorted and can be compared
zz = number
with zz out of 0x7y)
of coins
Coin was rejected as not mea-
Info
0xC000
sured within the acceptance
band programmed
Coin was accepted though
Info
0xC063
measured beyond the accep-
tance band programmed
Hardware error during coin
Info
0xC090
acceptance
Coin could not be accepted and
Info
was rejected as at least two
0xC091
coins entered the measurement
area at the same time
Coin could not be accepted due
Info
0xC093
to polling timeout
Coin was rejected as coin ac-
Info
0xC094
ceptance was not polled
Coin was rejected as coin posi-
Attention
tion sensors covered
0xC096
Coin was rejected as event
Info
0xC099
buffer is full
Coin was rejected as previous
Info
0xC09B
coin has not been accepted yet
Coin was rejected as previous
Info
0xC09C
coin has not been rejected yet
Sensor detected unknown
Info
0xC09D
object and no coin
Coin was rejected as validator
Info
0xC09E
misses coin to be accepted
CLS Advance
Remedy/hints
By whom
Insert coin(s) again
Customer
If info comes up repeatedly,
Service
configuration failure, contact
service
If info comes up repeatedly,
Service
configuration failure, contact
service
• Eliminate jam/foreign
• Attendant possessing
object
the key for the upper/
(cf. Chap. "8.5.1 Elimi-
nating coin jam in acceptance
lower lock
unit", p. 38)
• Cleaning, contact service
• Service
Insert coin again
Customer
Insert coin again
Customer
• Insert coin again
• Customer
• Cleaning, contact service
• Service
OM_CLS_-_EN_2-0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents