Fig. 52: Detail: Upper And Lower Status Illumination - CPI CLS Advance Operator's Manual

Coin recycler
Table of Contents

Advertisement

Troubleshooting
10
Troubleshooting
This chapter describes how to locate an error either using the
• Top and bottom illuminations [Fig. 52/1, 2] or
• Detailed status and error messages transmitted to the control software
10.1
Quick troubleshooting using status illumination
Lighting/Flashing
How long /often? Meaning
once
for 2s
steady ON
flashing
steady ON
flashing
flashing
steady ON
flashing
steady ON
46
Remedy, hints
Coin input funnel ready to operate. Self-test
No error.
OK.
Initialization successfully completed.
No error. Wait till illumination is on steadily to insert coins.
Stand-by mode: ready for coin insertion.
No error.
Processing coins.
No error.
Warning!
Wait till problem has been solved and illumination is green
Solving problem. Do not insert coins.
or blinking yellow.
Attention! (Depending on configuration)
No error.
• Processing coins. Do not insert coins.
• Wait till illumination is green to insert coins.
• Problem solved and recorded. Ready for
• Insert coins and note problem for next service (error
coin insertion.
• Error! Optics in coin input funnel covered.
• Remove foreign object from input funnel.
• Error! Optics in coin input funnel defective.
• Service case.
Error! Transaction failed. Out of service.
Service case.
Warning! Coin return tray is full.
Stop inserting coins till return tray has been emptied.
Coin payout unit is transporting coins to the
No error. Take change out of the coin return tray.
coin return tray.
record).

Fig. 52: Detail: Upper and lower status illumination

CLS Advance
OM_CLS_-_EN_2-0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents