CPI CLS Advance Operator's Manual page 49

Coin recycler
Table of Contents

Advertisement

CLS Advance
Error code Description/Cause
Category
Coin validator FW upgrade:
Attention
source and destination data
0x0ADB
is not same (IAP#10). FW
file is corrupt
Coin validator FW upgrade:
Attention
0x0ADC
flash programming hardware
interface is busy (IAP#11)
Coin validator FW upgrade:
Info
0x0ADD
coin validator is in boot-
loader mode
CLS system tried to write
Info
a table as specified by
0x0ADE
validator spec but validator
returned failed table writing
error
CLS system wrote a table as
Info
0x0ADF
specified by validator spec to
validator successfully
Coin return conveyor motor
Critical
failure. Return belt motor
0x0B01
was commanded to operate
but no current flow through
the motor was detected
Coin return conveyor motor
Attention
0x0B02
overcurrent likely due to
coin jam
Sensors in coin input funnel
Critical
blocked during power on
0x0E74
Sensors in coin input funnel
Critical
0x0E76
defective (no signal)
No manufacturing data
Critical
0x0E78
stored in coin input funnel
PDI and flash not protected
Critical
0x0E7A
Coin(s) seem(s) to be
Critical
stuck in input tray for over
2 minutes after successful
0x0E80
power-on
OM_CLS_-_EN_2-0
Remedy/hints
By whom
FW file failure, contact service
Service
Reset CLS
Service
• Connection/installation failure,
• Service
contact service
• Hardware replacement
• Service department,
CPI, Buxtehude
Eliminate coin jam or foreign objects
Attendant possessing
on the return belt
the key for the lower
lock
• Remove coins or foreign objects
• Attendant
from sensors
• If necessary, clean coin input
• Attendant
funnel
(cf. Chap. "8.4.1 Cleaning the
housing, coin input funnel and return
tray", p. 36)
Hardware replacement, contact
Service
service
Hardware replacement, contact
Service
service
Hardware replacement, contact
Service
service
• Remove coin(s) or foreign objects
• Attendant
from input funnel and power cycle
the CLS
• If necessary, clean coin input
• Attendant
funnel
(cf. Chap. "8.4.1 Cleaning the
housing, coin input funnel and return
tray", p. 36)
Error code Description/Cause
Category
Coin input funnel is in boot
Critical
0x0EDD
loader mode
Main PCB communication
Critical
failure. CLS control unit was
0x1165
unable to establish commu-
nication with the Main PCB
Main PCB FW upgrade:
Attention
0x11D4
invalid command (IAP#1).
FW file is corrupt
Main PCB FW upgrade:
Attention
source address is not on a
0x11D5
word boundary (IAP#2). FW
file is corrupt
Main PCB FW upgrade:
Attention
destination address is not on
0x11D6
a correct boundary (IAP#3).
FW file is corrupt
Main PCB FW upgrade: byte
Attention
count is not multiple of 4
0x11D7
or is not a permitted value
(IAP#6). FW file is corrupt
Main PCB FW upgrade:
Attention
0x11D8
sector number is invalid
(IAP#7). FW file is corrupt
Main PCB FW upgrade: sec-
Attention
0x11D9
tor is not blank (IAP#8). FW
file is corrupt
Main PCB FW upgrade: sec-
Attention
0x11DA
tor is not prepared (IAP#9).
FW file is corrupt
Main PCB FW upgrade:
Attention
source and destination data
0x11DB
is not same (IAP#10). FW
file is corrupt
Main PCB FW upgrade: flash
Attention
0x11DC
programming hardware
interface is busy (IAP#11)
Main PCB FW upgrade: Main
Critical
0x11DD
PCB is in boot loader mode
Power-on or ccTalk reset
Info
0x8000
command successful. CLS in
ready state
Troubleshooting
Remedy/hints
By whom
Firmware failure, contact service
Service
Hardware replacement, contact
Service
service
FW file failure, contact service
Service
FW file failure, contact service
Service
FW file failure, contact service
Service
FW file failure, contact service
Service
FW file failure, contact service
Service
FW file failure, contact service
Service
FW file failure, contact service
Service
FW file failure, contact service
Service
Reset CLS, contact service
Service
FW file failure, contact service
Service