Troubleshooting
Error code Description/Cause
Category
Hopper count match. Num-
Info
ber of hoppers identified are
0x8003
matching with the number of
configured in the system
Main controller warning. Its
Info
0x8011
free stack-based memory is
getting low
Main PCB firmware bundle
Attention
0x8023
version mismatch
Main PCB configuration
Attention
0x8024
bundle version mismatch
Hopper 1 firmware bundle
Attention
0x8123
version mismatch
Hopper 1 configuration
Attention
0x8124
bundle version mismatch
CLS control unit retrying
Info
communication after unsuc-
0x8164
cessfully attempting to com-
municate with a hopper 1
Hopper 1 replied with NACK
Info
0x8166
status code after sending
hopper a command
Hopper 1 replied with BUSY
Info
0x8167
status code after sending
hopper a command
Lack of change. CLS control
Attention
unit wants the hopper 1 to
0x8168
pay out more coins than
available
Hopper reset. Hopper 1
Info
0x8169
detected a power-up
Hopper 1 replied with wrong
Info
0x816A
checksum
Enter hopper 1 firmware
Info
0x81C8
update mode ACK
Begin hopper 1 firmware
Info
0x81C9
update ACK
Upload hopper 1 firmware
Info
0x81CA
ACK
Finish hopper 1 firmware
Info
0x81CB
update ACK
Hopper 2 firmware bundle
Attention
0x8223
version mismatch
50
Remedy/hints
By whom
FW file failure, contact service
Service
Configuration file failure, contact
Service
service
FW file failure, contact service
Service
Configuration file failure, contact
Service
service
Refill hopper
Attendant possessing
(cf. Chap. "8.1 Filling the
coin hoppers", p. 31)
the key for the lower
lock
FW file failure, contact service
Service
Error code Description/Cause
Category
Hopper 2 configuration
Attention
0x8224
bundle version mismatch
CLS control unit retrying
Info
communication after unsuc-
0x8264
cessfully attempting to com-
municate with a hopper 2
Hopper 2 replied with NACK
Info
0x8266
status code after sending
hopper a command
Hopper 2 replied with BUSY
Info
0x8267
status code after sending
hopper a command
Lack of change. CLS control
Attention
unit wants the hopper 2 to
0x8268
pay out more coins than
available
Hopper reset. Hopper 2
Info
0x8269
detected a power-up
Hopper 2 replied with wrong
Info
0x826A
checksum
Enter hopper 2 firmware
Info
0x82C8
update mode ACK
Begin hopper 2 firmware
Info
0x82C9
update ACK
Upload hopper 2 firmware
Info
0x82CA
ACK
Finish hopper 2 firmware
Info
0x82CB
update ACK
Hopper 3 firmware bundle
Attention
0x8323
version mismatch
Hopper 3 configuration
Attention
0x8324
bundle version mismatch
CLS control unit retrying
Info
communication after unsuc-
0x8364
cessfully attempting to com-
municate with a hopper 3
Hopper 3 replied with NACK
Info
0x8366
status code after sending
hopper a command
Hopper 3 replied with BUSY
Info
0x8367
status code after sending
hopper a command
CLS Advance
Remedy/hints
By whom
Configuration file failure, contact
Service
service
Refill hopper
Attendant possessing
(cf. Chap. "8.1 Filling the
coin hoppers", p. 31)
the key for the lower
lock
FW file failure, contact service
Service
Configuration file failure, contact
Service
service
OM_CLS_-_EN_2-0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents