c. (APPC) Control Unit Description Example
Type the command: CRTCTLAPPC
Parameter
CTLD (Controller Description)
LINKTYPE (Link type)
APPN (APPN-capable)
LINE (Attached nonswitched line)
MAXFRAME (Maximum frame size)
RMTNETID (Remote network identifier)
RMTCPNAME (Remote Control Point)
EXCHID (Exchange identifier)
STNADR (Station address)
EXCHID (Exhchange identification)
Node Type
d. Remote Workstation (RWS) Controller Description
Remote workstations are workstations that are located more than 1525 meters from an
AS/400 system. By making use of the Model 3494 Twinax Controller, workstations in
different buildings, different cities or even different countries can access an AS/400 system.
Type the command: CRTCTLRWS
Parameter
CTLD (Controller description)
TYPE (Controller type)
MODEL (Controller model)
LINKTYPE (Link type)
RMTLOCNAME (Remote location name)
RMTNETID (Remote network identifier)
AS/400 System Configuration
Value
SDLCAPPC
*SDLC
YES
SDLCLine
521
*NETATR
SDLCCP
07300002
02
07300002
*LENNODE
Value
SDLCRWS
3494
2
*NONE
SDLCCP
*NETATR
7