Decision Data 3000 Series User Manual page 104

Table of Contents

Advertisement

B1
No LU-to-LU session
C0
DTE specific general
C1
Termination pending
C2
Channel Inoperative
C3
Unauthorized interrupt confirmation
C4
Unauthorized interrupt request
C5
PU (PVC) Not available
C6
Inactivity time-out
D0
F4
General Resources. Retry the operation. Other applications may operate
D1
Buffers depleted
D2
F5
PIU too long Retry the operation. Other applications may operate
E0
69
Local Procedure General error Report the error to the host system
E1
Packet with LC=0 not received
E2
Restart or Diagnostic Packet on LCI ±`0'
E3
Incoming call received on wrong LC
E4
Facility not subscribed
E5
Packet does not Restart, or Diag on LCI=`0'
E6
42
Facility parameters not supported. Report the error to the host system
operator.
E7
41
Facility not supported. Report the problem to the host system operator.
E8
46
Unexpected calling DTE. Ensure that the network address is correct.
Retry the operation. Report the problem to the host system operator if
E9
Invalid `D' bit request
EA
Reset indication on virtual call
EB
Invalid protocol identifier
EC
Connection identifier mismatch
ED
Missing Cause/Diagnostic code
F0-FF
Remote procedure general error
00
No additional information
20
Packet not allowed
Error Identification
A-17

Advertisement

Table of Contents
loading

Related Products for Decision Data 3000 Series

This manual is also suitable for:

Stk3494/3494

Table of Contents