Device Configuration; Twinax Device Configuration Procedure - Decision Data 3000 Series User Manual

Table of Contents

Advertisement

7Device Configuration

The Model 3494 controller supports Twinax devices. It enables you to define the
following attributes for the Twinax devices attached to the controller: location, type,
language, and PU sessions of the devices. Two types of device configurations are
available: default and manual. Using default configuration the system automatically
identifies connected Twinax devices and maps them while manual configuration enables
a more flexible configuration procedure.
This chapter will describe the Twinax devices configuration procedure.

7.1Twinax Device Configuration Procedure

1. Access the device configuration screen by selecting 7. Device Configuration from
the Main menu.
The following screen is displayed:
The Twinax Adapter Map in the upper half of the screen illustrates the exact location
of the devices on each adapter and port, as well as the Keyboard Language
assigned to each one.
Up to seven Twinax devices can be connected to each port. Eight ports are
displayed, each row representing a Twinax port and each column a Twinax address.
The lower part of the screen is the LSID Map that shows virtual mapping of devices
for each PU.
2.
You may either use the default configuration or manually define the devices
connected to the controller.
1

Advertisement

Table of Contents
loading

Related Products for Decision Data 3000 Series

This manual is also suitable for:

Stk3494/3494

Table of Contents