Decision Data 3000 Series User Manual page 109

Table of Contents

Advertisement

Error Identification
1BCC00, System Reference Codes
A restart request packet was issued by the 3494 after detecting an error.
[CC] is the cause code. A description of each code follows:
SNA
ISO
Description
Cause
Cause
Code
Code
11
11
34 34
Restart Confirmation packet not received within 200 seconds.
A5
A5
Diagnostic packet received.
A6
A6
Packet too short
A7
A7
Packet too long
A8
28
Invalid GFI (Restart Indication/Confirmation only)
E2
29
LCID is not equal to 0 on Restart Indication/Confirmation
E5
24
LCID=0 on non-Restart/Diagnostic packet
400000 - 400900, Linking Errors
Error
Description and Suggested Recovery
Code
400000
A connection attempt is in progress - wait for logon screen
400100
Failed connection - Retry.
400200
Data entered in wrong format. [H] must be first.
400300
You have selected the wrong AS/400 System to disconnect from - correct
400400
The Controller is not configured for the selected AS/400 System.
400500
Incorrect command for the first configuration.
400600
Invalid request format.
400700
Connection number is not configured for the selected AS/400 System.
400800
Link already exists.
400900
Controller is already establishing link.
A-22
Unsolicited Restart Confirmation received.