VERSION 12/2018
8

CLEANING AND MAINTENANCE

8.1

CLEANING

8.1.1 CLEANING PERSONNEL

Cleaning work should be undertaken regularly and carefully by qualified and trained personnel.
They should be informed of specific hazards during their training.
The following hazards may arise during cleaning work:
– risk to health from inhaling solvent vapors,
– use of unsuitable cleaning tools and aids.

8.1.2 FLUSHING AND CLEANING THE SPRAY GUN

NOTICE
Impurities in the spraying system
Spray gun blockage, products harden in the system.
Flush the spray gun and paint supply with a suitable cleaning agent.
NOTICE
Flushing agent in the air duct!
Functional faults caused by swollen seals.
Always point the spray gun down when cleaning.
Never immerse the spray gun in cleaning agent.
The spray gun and the device must be cleaned and flushed daily. The cleaning/flushing
agents used for cleaning or flushing must correspond with the working material.
1. Relieve the pressure of the spray gun and device.
2. Secure spray gun (Remove control air hose).
3. Connect the cleaning agent supply.
4. Dismount the Airless nozzle and clean it separately (see Chapter 7.2.3).
5. Pressurize the cleaning agent supply to a maximum pressure of 4 MPa; 40 bar; 580 psi
and thoroughly flush the spray gun.
6. Relieve the pressure of the spray gun and device.
7. Secure spray gun (Remove control air hose).
8. Clean outside of spray gun with a cleaning agent recommended by the lacquer
manufacturer and dry with a cloth or blow gun.