7 .3 Analogue outputs

The analogue outputs are galvanically isolated from the electronic control unit FC100-CA .
Connector pin assignment for analogue outputs V1, V2 and C1:
Analogue output 1 - ANA OUT FLOW (flow output)
Analogue output 2 - ANA OUT TEMP (temperature output)
* Shield ungrounded - apply on one side only
The output is reverse polarity protected.
Insulation voltage: analogue output - central electronic unit DC 500 V
FC100-CA | Flow Meter
TECHNICAL DATA
Signal name
NC
analogue output 1 - flow
reference ground 1
shield 1 *
shield 2 *
analogue output 2 - temperature
reference ground 2
NC
NC - not used
Pin XAO
1
2
3
4
5
6
7
8
63