Operating Mode - Flow vision FC100 - CA User Manual

Flow meter
Table of Contents

Advertisement

5 .6 Operating mode

submenu
OPERATING MODE
back to
CONFIGURATION
menu
Volume flow can be indicated either as:
• STANDARD FLOW
or as
• OPERATING FLOW
The physical details are described in chapter 1.1, "Measuring procedure".
The following volume flow and velocity values and those indicated on the display are set to standard
or operating conditions by this setting.
Caution!
As under normal operating conditions pressure changes may arise, which cannot be taken
into account when calculating operating volume flow, it is recommend to prefer the standard
flow setting.
FC100-CA | Flow Meter
CONFIGURATION
OPERAT. SELECT
STANDARD FLOW
M
1.013 mbar/14.7PSI
0°C/32,0 °F
M
Standard volume flow equals operating volume flow at 1013 mbar/
14.69 psi and 0 °C/32 °F
Operating volume flow is calculated by the standard volume flow,
considering the pressure set (see chapter. 5.2) and the medium tem-
perature
OPERAT. SELECT
OPERATING FLOW
M
7.00 bar/102 PSI
MEASURED PRESS.
M
fig. 36
49