Monitoring Heads Cst And Csf; Temperature Measurement - Flow vision FC100 - CA User Manual

Flow meter
Table of Contents

Advertisement

Flow Meter | FC100-CA

7 .5 . 1 .2 Monitoring heads CST and CSF-...

Flow measurement ranges:
The flow measurement range is determined by the inside pipe diameter (see table).
It can be calculated with the following equation:
Inside pipe diameter
D in mm
20
30
40
50
60
70
80
90
100
150
200
250
300
400
500
600
700
800
900
1000
Setting range for inside pipe diameter:
Velocity range:
1)
Accuracy
:
Repeatability (5% MBE to 100% MBE):
Temperature drift:

7 .5 .2 Temperature measurement

Measuring range:
Accuracy:
68
TECHNICAL DATA
Q = V
x A
N
R
3
Q [Nm
/h] - flow quantity
V
[m/h] - average standard velocity
N
2
A
[m
] - inside pipe cross-section
R
Measuring range
3
in Nm
/h
76
173
307
480
692
942
1230
1557
1922
4325
7690
12016
17303
30762
48066
69215
94210
123049
155734
192265
10.0 mm ... 999.9 mm
0 ... 68 Nm/s (100 Nm/s)
± 5 % MW ** / ±0.5 % MBE *
± 1 % MW / ±0.5 % MBE
± 0.05 %/K/MBE
- 40 ... +130 °C / -40 ... +266 °F
±1 % MB ***
Display range
3
in Nm
/h
113
254
452
706
1017
1385
1809
2290
2827
6361
11309
17671
25446
45238
70685
101787
138544
180955
229021
282743