Sign In
Upload
Manuals
Brands
Flow vision Manuals
Measuring Instruments
FC01-Ex
Flow vision FC01-Ex Manuals
Manuals and User Guides for Flow vision FC01-Ex. We have
1
Flow vision FC01-Ex manual available for free PDF download: User Handbook Manual
Flow vision FC01-Ex User Handbook Manual (84 pages)
Brand:
Flow vision
| Category:
Measuring Instruments
| Size: 1.26 MB
Table of Contents
Table of Contents
3
1 Description
8
2 Ex Atmosphere - Definitions and Mounting Instructions
8
Information on Explosion Protection
8
Classification Zones
9
Equipment Group II, Category 1 (Zones 0 and 20)
9
Equipment Group II, Category 2 (Zones 1 and 21)
9
Equipment Group II, Category 3 (Zones 2 and 22)
9
Materials Used for Calorimetric Monitoring Heads
10
Stainless Steel 1.4571/AISI 316 Ti
10
Nickel-Based Alloy Hastelloy C4/2.4610
10
Titanium G7, 3.7235
10
Temperature Limits
11
Gases
11
Dust
11
Cable Length
11
Installation - Ex-Components
12
Installation - Calorimetric Monitoring Head
12
Mechanical Installation - Thread-Mounted Monitoring Head CST-Ex
12
Mounting Instructions
13
Liquid Media
14
Depth of Threading
15
Gases
15
Sealing
15
Electrical Connection
16
Installation of Electronic Control Unit FC01-Ex
18
Electrical Connection
18
Mechanical Installation
18
Circuit Diagram FC01-Ex
21
(Version FC01-Ex-U1T4)
22
Electrical Connection - Frequency Output
22
Maintenance
24
Monitoring Head CST-Ex
24
Flow Meter FC01-Ex
24
3 Normal Atmosphere - Definitions and Mounting Instructions
25
Measuring Procedure
25
System Description
26
User Interfaces
27
Customer Calibration
29
Options and Advantage of Customer Calibration
29
Special Flow and Installation Conditions
29
How to Achieve Higher Accuracy
30
How to Achieve the Full Scale Range
30
Pin-Point Adjustment (Selective Accuracy)
30
Reproduction of Precise Measuring Instruments
30
Use of Standard Monitoring Heads
30
4 Technical Implementation of Customer Calibration
31
Calculation
31
Calibration
31
Selection of CTD Value (Temperature Differential)
31
Trim Point Selection - Number and Position
34
MAX-MIN Calibration Procedure
34
Zero Point, Directional Discrimination and Upper Characteristic Curve Value
35
New Curve / Old Curve
35
New Curve
35
Old Curve
36
Transfer of C- and T Values - Re-Establishment of T Value
36
Establishing the T Value - General
36
Establishing the New T Value
37
Expanding the Characteristic Curve
38
5 Operation
39
Operating System
39
Configuration
41
Access to Menu Option CUSTOMER TRIM
41
Custom Designed Calibration (Menu Option: CUSTOMER TRIM)
41
Medium Selection (Menu Option: MEDIUM SELECT)
41
Monitoring Head Data (Menu Option: SENSOR CODE)
41
Selection of Monitoring Head (Menu Option: SENSOR SELECT)
41
Automatic Calibration
42
Determining the Temperature Differential
42
Manual Calibration
42
Number of Trim Points
42
Old Curve / New Curve
42
Calibration Temperature
43
Potential Errors During the Calibration
43
Storing the Characteristic Curve
43
Limit Switch Combinations (Menu Option: LIMIT SWITCHES)
44
Display (Menu Option: DISPLAY SELECT)
45
Flow Rate Unit (Menu Option: FLOW UNIT)
45
Medium Temperature Unit (Menu Option: TEMP. UNIT)
45
Bar Graph (Menu Option: BARGRAPH)
46
Pipe Size (Menu Option: PIPE SIZE)
46
Frequency Output (Menu Option: FREQUENCY OUTPUT)
47
Analogue Output - Flow Rate (Menu Option: ANA out FLOW)
48
Analogue Output - Medium Temperature (Menu Option: ANA out TEMP.)
48
Quitting the Configuration Menu
48
Configuration Menu
50
Configuration Submenus
51
Parameter Selection
55
Limit Switch 1 - Switch-Off Value (Menu Option: LS1 off
55
Limit Switch 1 - Switch-On Value (Menu Option: LS1 on
55
Measuring Time (Menu Option: MEAS. TIME)
55
Limit Switch 2 - Switch-Off Value (Menu Option: LS2 off
56
Limit Switch 2 - Switch-On Value (Menu Option: LS2 on
56
Quitting the Parameter Selection Menu
56
Scaling Factor (Menu Option: FLOWSCALE*)
56
Parameter Selection Menu
58
6 On-Line Phases
59
Switch-On Performance
59
Measuring Cycle
59
Operating Data
59
Measured Value(S)
59
Last Error (Menu Option: LAST ERROR)
61
Peak Values (Menu Option: PEAK VALUE MIN / PEAK VALUE MAX)
61
Main Menu
62
7 Errors
63
Test and Diagnosis
63
Priority Group I
63
Priority Group II
63
Priority Group III
63
Potential Errors
64
8 Technical Data
66
Ambient Conditions FC01-Ex
66
Monitoring Head CST-Ex
66
Electrical Characteristics
66
Power Supply
66
DC Voltage Supply
67
Analogue Outputs
68
Voltage Output V1 - 5 V FS
68
Voltage Output V2 - 10 V FS
68
Current Output C1 - 20 Ma FS
69
Signal Outputs
69
Relay Outputs R2 (Change over Contacts, DC or AC Switching Voltage)
69
Transistor Outputs (DC Switching Voltage)
70
Metrological Data
71
Mass Flow Measurement
71
Temperature Measurement
71
FC01-Ex Electronic Control Unit
71
Sensor Interface - Electrical Data
72
9 Examples
73
Example 1: Calorimetric Monitoring Head- Medium Water - New Curve
73
Example 2: Distribution of Trim Points
79
Appendix 1 - Performance of the Digital and Analogue Outputs During the Operating and Error Modes
81
Appendix
81
Advertisement
Advertisement
Related Products
Flow vision FC01-Ex-U1T4
Flow vision FC 01- CA
Flow vision FC50-EX-CA
Flow Vision FC50-EX
Flow Vision FC50
Flow vision FC50-CA
Flow vision FC50-dbEX-CA
Flow vision FC50-dbEX
Flow vision FC100 - CA
Flow vision FS20-dbEX
Flow vision Categories
Measuring Instruments
Monitor
More Flow vision Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL