Number
CS lack of usage notification time, in
Q501
0- 255 Days
days (0- 255)
Q502
Periodic test, in days (0-255)
0-255 Days
Enabled
Q503
Programming mode entry reports to CS
Disabled
Enabled
Q504
Trouble reports to CS
Disabled
Enabled
Q505
Trouble restore reports to CS
Disabled
Enabled
Q506
Manual bypass reports to CS
Disabled
Enabled
Q507
Bypass restore reports to CS
Disabled
Enabled
Q508
Force bypass reports
Disabled
Enabled
Q509
AC loss reports to CS
Disabled
Enabled
Q510
AC restore reports to CS
Disabled
Enabled
Q511
System low battery reports to CS
Disabled
Enabled
Q512
System low battery restore reports to CS
Disabled
Enabled
Q513
RF low battery reports
Disabled
Enabled
Q514
Sensor low battery restore reports to CS
Disabled
Enabled
Q515
System disarmed reports to CS
Disabled
Enabled
Q516
System armed reports to CS
Disabled
Enabled
Q517
Alarm restore reports to CS
Disabled
Enabled
Q518
Smart test reports
Disabled
2GIG EDGE Installation Guide
Factory Default
Programming
Page Reference
Setting
Category
7 Days
Reporting
52
30 Days
Reporting
53
Disabled
Reporting
53
Enabled
Reporting
53
Enabled
Reporting
53
Disabled
Reporting
53
Disabled
Reporting
53
Disabled
Reporting
53
Enabled
Reporting
54
Enabled
Reporting
54
Enabled
Reporting
54
Enabled
Reporting
54
Enabled
Reporting
54
Enabled
Reporting
54
Disabled
Reporting
54
Disabled
Reporting
54
Disabled
Reporting
55
Disabled
Reporting
55
64

ANSI/SIA CP-01-2010 Features to Limit False Alarms

For compliance with ANSI/SIA CP-01-2010: Control Panel Standard - Features for False Alarm Reduction, the installer can set a variety of
different options designed to limit occurrences of a False Alarm.
ANSI/SIA CP-01-2010
2GIG System Feature
4.2.2.1
Exit Time
Exit Delay
4.2.2.2
Progress Annunciation
Exit Delay Announcement
4.2.2.3
Exit Time Restart
Exit Delay Restart
4.2.2.4
Exit Error
Exit Error
4.2.2.5
Unvacated Premises
Auto Stay
4.2.3.1
Entry Delay
Entry Delay
4.2.3.2
Progress Annunciation
Entry Delay Announcement
4.2.3.3
Disarm
Disarming Features
4.2.4.1
Control Buttons
Keyfob/Remote Arming Mode on System Not Ready.
4.2.4.2
Manual Alarms
Emergency Alarm Features
Alert Keyfob Disarming After Alarm
4.2.4.3
System Acknowledgment
Keyfob Arm/Disarm Confirmation
4.2.4.4
Remote Arming
Key Fob Arming
4.3.4.5
Remote Disarming
Key Fob Arming
4.2.5.1
Abort Window
Abort Window Dialer Delay
4.2.5.1.1
Disarm
Abort Window Dialer Delay
4.2.5.1.2
Abort
Abort Window Dialer Delay
4.2.5.2
Alarm Transmission
Abort Window Dialer Delay
4.2.5.3
Disarm
Disarm
4.2.5.4
Cancel Window
Alarm Cancel Time, Alarm Cancel Display
4.2.6.1
Use of Duress Feature
User Duress Report
4.2.6.2
Duress Code
Duress Code
4.2.7
Initiation of Manual Alarms
Panic, Fire, or Emergency Alarm
4.3.
Cross Zoning
Cross Sensor Zones, Cross Sensor Timeout
4.3.2
Swinger Shutdown
Swinger Shutdown Count (1-6)
4.3.3
Fire Alarms
Fire & Carbon Monoxide Protection
Console Test
4.6.3
System Test
Sensors Test
Installation & Programming Guide
"Q201: Exit delay, in seconds (45-120)"
"Q116: Allow quick exit"
"Q201: Exit delay, in seconds (45-120)"
"Q115: Exit delay restart"
See the 2GIG EDGE User Guide
"Q114: Auto stay"
"Q202: Entry delay 1, in seconds (30-240)"
"Q203: Entry delay 2, in seconds (30-240)"
"Q101: Enter installer code (4 or 6 digits)"
See the 2GIG EDGE User Guide
"Q121: Keyfob/remote arming mode on system not ready"
See the 2GIG EDGE User Guide
"Q119: Alert on disarm with keyfob after alarm"
"Q120: Keyfob arm/disarm confirmation"
"Q119: Alert on disarm with keyfob after alarm"
"Q120: Keyfob arm/disarm confirmation"
"Q205: Alarm abort window transmission delay"
"Q502: Periodic test, in days (0-255)"
"Q502: Periodic test, in days (0-255)"
"Q205: Alarm abort window transmission delay"
See the 2GIG EDGE User Guide
"Q204: Alarm cancel time, in minutes (5-255)"
"Covert Distress Signal"
"User Duress Pin"
See the 2GIG EDGE User Guide
"Q123: Cross sensor zones 99-100"
"Q209: Cross sensor timeout, in seconds (10-120)"
"Q208: Swinger shutdown count (1-6)"
"Q517: Alarm restore reports to CS"
"Sensor Type — 24-Hour Fire"
"Sensor Type — 24-Hour Fire Verification"
"Testing the System"