Cisco ESW 500 Administration Manual page 393

Cisco systems switch user manual
Hide thumbs Also See for ESW 500:
Table of Contents

Advertisement

Managing System Logs
Remote Log Servers
ESW 500 Series Switches Administration Guide
Add Syslog Server Page
Add Syslog Server Page
The
Servers.
Add Syslog Server Page
The
Log Server IP Address — Specifies the server to which logs can be sent.
UDP Port — Defines the UDP port to which the server logs are sent. The
possible range is 1 to 65535. The default value is 514.
Facility — Defines a user-defined application from which system logs are sent
to the remote server. Only one facility can be assigned to a single server. If a
second facility level is assigned, the first facility is overridden. All applications
defined for a device utilize the same facility on a server. The field default is
Local 7. The possible field values are Local 0 - Local 7.
Description — Provides a user-defined server description.
Minimum Severity — Indicates the minimum severity level of logs that are sent
to the server. For example, if Notice is selected, all logs from a Notice severity
and higher are sent to the remote server.
The following are the available log severity levels:
-
Emergency
functioning properly, an emergency log message is saved to the
specified logging location.
-
Alert
— The second highest warning level. An alert log is saved, if there
is a serious device malfunction; for example, all device features are
down.
contains fields for defining new Remote Log
contains the following fields:
— The highest warning level. If the device is down or not
16
382

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents