Configuring Device Security
Defining Dynamic ARP Inspection
STEP 1
ESW 500 Series Switches Administration Guide
Click Security > ARP Inspection > Properties. The
opens:
ARP Inspection Properties Page
ARP Inspection Properties Page
The
•
Enable ARP Inspection — Enables ARP Inspection on the device. The possible
field values are:
-
Checked
— Enables ARP Inspection on the device.
-
Unchecked
value.
•
ARP Inspection Validate — Enables ARP Inspection Validation on the device.
The possible field values are:
-
Checked
— Enables ARP Inspection Validation on the device. Source
MAC, Destination MAC, and IP addresses are checked in ARP requests
and responses.
-
Unchecked
the default value.
contains the following fields:
— Disables ARP Inspection on the device. This is the default
— Disable ARP Inspection Validation on the device. This is
ARP Inspection Properties Page