Daikin AWST18SU14 AA Series Installation Instructions Manual

Daikin AWST18SU14 AA Series Installation Instructions Manual

Hide thumbs Also See for AWST18SU14 AA Series:

Advertisement

VERTICAL MOUNT AIR HANDLERS
INSTALLATION INSTRUCTIONS & OPERATING INSTRUCTIONS

1 Important Safety Instructions

As a professional installer, you have an obligation to know
the product better than the customer. This includes all safety
precautions and related items. Prior to actual installation,
thoroughly familiarize yourself with this Instruction Manual.
Pay special attention to all safety warnings. Remember, it is
your responsibility to install the product safely and to know it
well enough to be able to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of thinking before
acting. Most dealers have a list of specific, good safety
practices...follow them.
The precautions listed in this Installation Manual are in- tended
as supplemental to existing practices. However, if there is a
direct conflict between existing practices and the content
of this manual, the precautions listed here take precedence.
HIGH VOLTAGE
DISCONNECT ALL POWER BEFORE SERVICING
OR INSTALLING THIS UNIT. MULTIPLE POWER
SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH.
ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL,
ADJUST, SERVICE OR REPAIR(HEREINAFTER, "SERVICE")
THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD
SERVICE THE EQUIPMENT. THE MANUFACTURER WILL
NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY
DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE
PROCEDURES. IF YOU SERVICE THIS UNIT, YOU ASSUME
RESPONSIBILITY FOR ANY INJURY OR PROPERTY
DAMAGE WHICH MAY RESULT. IN ADDITION, IN
JURISDICTIONS THAT REQUIRE ONE OR MORE LICENSES
TO SERVICE THE EQUIPMENT SPECIFIED IN THIS
MANUAL, ONLY LICENSED PERSONNEL SHOULD SERVICE
THE EQUIPMENT.
IMPROPER INSTALLATION, ADJUSTMENT, SERVICING OR
REPAIR OF THE EQUIPMENT SPECIFIED IN THIS MANUAL,
OR ATTEMPTING TO INSTALL, ADJUST, SERVICE OR REPAIR
THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT
PROPER TRAINING MAY RESULT IN PRODUCT DAMAGE,
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
TO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL
INJURY, OR DEATH, DO NOT STORE COMBUSTIBLE MATERI-
ALS OR USE GASOLINE OR OTHER FLAMABLE LIQUIDS OR
VAPORS IN THE VICINITY OF THIS APPLIANCE.
IO-4005
08/2022
WARNING
WARNING
WARNING
© 2022
19001 Kermier Rd., Waller, TX 77484
www.daikinac.com
P/N: IO-4005
Date: August 2022
HAVE YOUR CONTRACTOR IDENTIFY ALL THE VARIOUS CUT
OFF SWITCHESAND DEVICES THAT SERVICE THIS UNIT.
KNOW WHERE THE SWITCH IS THAT WILL CUT OFF ENERGY
TO THE HEATING SYSTEM IN THE EVENT OF OVERHEATING.
THIS APPLIANCE IS NOT INTENDED FOR THE USE BY PER-
SONS (INCLUDING CHILDREN) WITH THE REDUCED PHYSICAL,
SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERI-
ENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING USE OF THE
APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY
DO NOT PLAY WITH THE APPLIANCE.
THIS UNIT SHOULD NOT BE CONNECTED TO, OR USED IN
CONJUNCTION WITH, ANY DEVICES THAT ARE NOT DESIGN
CERTIFIED FOR USE WITH THIS UNIT OR HAVE NOT BEEN
TESTED AND APPROVED BY THE MANUFACTURER. SERIOUS
PROPERTY DAMAGE OR PERSONAL INJURY, REDUCED UNIT
PERFORMANCE AND/OR HAZARDOUS CONDITIONS MAY
RESULT FROM THE USE OF DEVICES THAT HAVE NOT BEEN
APPROVED OR CERTIFIED BY THE MANUFACTURER.
CONTENTS
1 Important Safety Instructions ............................. Pg. 1
2 Shipping Inspection ........................................... Pg. 2
4 Replacement Parts .............................................. Pg. 2
5 Pre- Installation Instructions .............................. Pg. 2
5.1 Preparation ...................................................... Pg. 2
5.2 System Matches .............................................. Pg. 2
5.3 Interconnecting Tubing .................................... Pg. 3
6 Application Information ...................................... Pg. 3
6.1 Wire Sizing ...................................................... Pg. 3
6.4 Fresh Air Openings ......................................... Pg. 4
7.1 Tubing Size ..................................................... Pg. 4
7.2 Tubing Connection .......................................... Pg. 4
8 Maintenance Check ............................................ Pg. 5
9 Wiring Diagrams and Air Flow Data ................... Pg. 6
9.1 Low Voltage Connection ................................. Pg. 6
10 Trouble Shooting .............................................. Pg. 11
CAUTION
CAUTION
WARNING

Advertisement

Table of Contents
loading

Summary of Contents for Daikin AWST18SU14 AA Series

  • Page 1: Table Of Contents

    VERTICAL MOUNT AIR HANDLERS © 2022 19001 Kermier Rd., Waller, TX 77484 INSTALLATION INSTRUCTIONS & OPERATING INSTRUCTIONS www.daikinac.com P/N: IO-4005 Date: August 2022 1 Important Safety Instructions CAUTION As a professional installer, you have an obligation to know the product better than the customer. This includes all safety HAVE YOUR CONTRACTOR IDENTIFY ALL THE VARIOUS CUT precautions and related items.
  • Page 2: Shipping Inspection

    3 Codes & Regulations This product is designed and manufactured to comply with n to know national codes. Installation in accordance with such codes cludes all and/or prevailing local codes/regulations is the respon-sibil- actual in- ity of the installer. The manufacturer assumes no respon- h this In- sibility for equipment installed in violation of any codes or ety warn-...
  • Page 3: Interconnecting Tubing

    5.3 Interconnecting Tubing: Electrical Supply Wire and MOP Give special consideration to minimize the length of refrig- WARNING erant tubing when installing air handlers. Refer to Remote Cooling/ Heat Pump Service Manual RS6200006, and TP- HIGH VOLTAGE 107 Long Line Set Application R-410A for tubing guidelines. TO AVOID THE RISK OF FIRE OR EQUIPMENT If possible, allow adequate length of tubing such that the DAMAGE, USE ONLY COPPER CONDUCTORS.
  • Page 4: Maximum Overcurrent Protection (Mop)

    6.4 Fresh Air Openings Maximum Allowable Length in Feet All AWST models include 4” fresh air knockouts to Limit Voltage Drop to 2%* on both sides of the cabinet. To utilize, simply remove the Minimum Circuit Ampacity (MCA) appropriate knockout and connect fresh air inlet venting Wire Size (AWG) directly to cabinet.
  • Page 5: Thermal Expansion Valve System Adjustment

    7.3 Thermal Expansion Valve System Adjustment Run the system at Cooling for 15 minutes until refrigerant pressures stabilize. Use the following guidelines and methods to check unit operation and ensure the refrigerant charge is within limits. Charge the unit on low stage. 1.
  • Page 6: Wiring Diagrams And Air Flow Data

    9 Wiring Diagrams and Air Flow Data CABINET DIMENSIONS CABINET DIMENSIONS LARGE CHASSIS SMALL CHASSIS ELECTRICAL POWER SUPPLY LARGE CHASSIS SMALL CHASSIS 2.5 & 3.0 TON 1.0, 1.5, & 2.0 TON LOW VOLTAGE POWER SUPPLY SUCTION LINE 2.5 & 3.0 TON 1.0, 1.5, &...
  • Page 7 BLOWER CHART FOR VERTICAL MOUNT AIR HANDLERS CFM delivered against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" Model Speed AWST18SU14** AA AWST24SU14** AA AWST30LU14** AA 1079 1025 1168 1127 1083 1050 1005 1114 1072 1031 1114 1072 1031 AWST36LU14** AA 1225 1191 1152...
  • Page 8 WIRING DIAGRAM AWST18SU14** WIRING DIAGRAM AWUF19**16 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 9 WIRING DIAGRAM AWST24SU14** WIRING DIAGRAM AWUF25**16 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 10 WIRING DIAGRAM AWST30LU14**, AWST36LU14** WIRING DIAGRAM AWUF31**16, AWUF32**16, AWUT31**16, AWUF32**16 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 11: Trouble Shooting

    10 Expansion Valve Troubleshooting Before replacing an expansion valve, check the following items: 1. Bulb location: Must be tightly secured to the suction line upstream of the equalizer connection. 2. Insulation: Bulb must be properly insulated. 3. Equalizer: Must be connected to the 1/4” SAE connection on the suction line. 4.
  • Page 12 SPLIT SYSTEMS AIR CONDITIONING AND HEAT PUMP HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDATIONS We strongly recommend a biannual maintenance checkup be performed before the heating and cooling seasons begin by a qualified servicer. Replace or Clean Filter IMPORTANT NOTE: Never operate unit without a filter installed as dust and lint will build up on internal parts resulting in loss of efficiency, equipment damage and possible fire.
  • Page 13 TART HECKLIST...
  • Page 14 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 15 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 16 CUSTOMER FEEDBACK We are very interested in all product comments. Please fill out the feedback form on one of the following links: Daikin Products: (https://daikincomfort.com/contact-us) Goodman® Brand Products: (http://www.goodmanmfg.com/about/contact-us). DAIKIN GOODMAN® BRAND Amana® Brand Products: (http://www.amana-hac.com/about-us/contact-us). You can also scan the QR code on the right for the product brand you purchased AMANA®...