Adjusting The General Purpose Output Duration; Setting The Time Of The Event Registers - evertz 8010TM Instruction Manual

Sdi time code master
Hide thumbs Also See for 8010TM:
Table of Contents

Advertisement

Model 8010TM SDI Time Code Master Manual
GPO1 ASSIGNMENT
Gpo1 = rdr event
Gpo1 = gen event
Gpo1 = 1 pulse/sec
Gpo1 = 1 pulse/min
Gpo1 = ref failure

3.7.9.4. Adjusting the General Purpose Output Duration

GPO DURATION
Gpo duration 01

3.7.9.5. Setting the Time of the Event Registers

When one of the GPO assignments is set to GEN EVENT the output activates based on the time
entered into the GEVT register. When one of the GPO assignments is set to RDR EVENT the output
activates based on the time entered into the REVT register.
To access the GEVT and REVT registers press the SHIFT+DISPLAY buttons one or more times until
the display prompt is GEVT or REVT. The ENTER and CLEAR keys are used in conjunction with the
numeric keys to set the value stored in the event registers. Enter a valid time into the desired register
following the same method used to enter the generator time. The event register may then be 'armed' as
follows:
Page 3-34
The following descriptions indicate how the GPO will function with each
setting.
Rdr event
The output will activate for the GPO Duration when the
reader time matches the REVT register and the event register is
armed. See section 3.7.9.5 for information about setting the
REVT register and arming it.
Gen event
The output will activate for the GPO Duration when the
generator time matches the GEVT register and the event
register is armed. See section 3.7.9.5 for information about
setting the GEVT register and arming it.
1 pulse/sec
The output will activate for the GPO Duration at the
beginning of each second of the generator time. The GPO
Duration value such that the pulse is less than one half a second
long.
1 pulse/min
The output will activate for the GPO Duration at the
beginning of each minute of the generator time.
Ref failure
The output will activate when a proper Gen Lock video
reference is missing.
Lock video returns.
The GPO DURATION menu item is used to adjust the duration (in
frames) of both of the general purpose outputs. Use the  OR  keys
to change the duration. Note that when the GPO ASSIGNMENT is set
to Ref failure the respective output will remain low until the Gen Lock
video returns.
Revision 1.5.1
he output will remain active until the Gen
T