Controlling The Vitc Reader 'Look Ahead' Compensation; Configuring Whether The Vitc Reader Will Display Local Time Or Utc Time In Time/Date Mode; Character Generator Functions - evertz 8010TM Instruction Manual

Sdi time code master
Hide thumbs Also See for 8010TM:
Table of Contents

Advertisement

3.5.7. Controlling the VITC Reader 'Look Ahead' Compensation

VITC RDR DISPLAY
VR disp process
VR disp direct
3.5.8. Configuring Whether the VITC Reader will Display Local Time
or UTC Time in Time/Date Mode
VITC RDR TZ ADJ
Vtm zone adj utc
Vtm zone adj loc
3.6.

CHARACTER GENERATOR FUNCTIONS

The 8010TM has six independently positionable character windows to display the generator and LTC
and VITC reader time and user bits. The four arrow keys (, , , ) control the position of all the
windows. The CHAR GEN ON/OFF key selects whether the video character generator (VCG) keyer is
on or off. The use of these keys in combination with the CHAR GEN WINDOW key selects which
windows are displayed and their position on the screen.
Five items on the programming menu are used to configure the character size, style, and whether
frames, fields and symbols should be displayed in the character generator. The following descriptions
appear in the order they appear on the menu.
OPERATION
Model 8010TM SDI Time Code Master Manual
The VITC RDR DISPLAY menu item is used to select whether the
normal 'look ahead' compensation for VITC reader dropouts is active or
not. Normally, the data is read in one field and displayed with an 'add 1
field' compensation.
disable this feature and to display exactly what is being read. The
topmost positions of the character generator are not available when in
the direct mode.
Select VR disp direct to enable DIRECT display mode.
displayed exactly as it is read without 'look ahead' compensation.
Displays from the VITC reader will be 1 field late and cannot be
positioned at the very top of the raster. DIRECT mode is usually used
for diagnostic purposes only.
Select VR disp process to enable normal 'look ahead' compensation.
Displays from VITC reader will be 'on time' but will NOT follow code
discontinuities immediately. PROCESSED mode should be used for
normal operations.
When the VITC
RDR MODE
VITC RDR TZ ADJ menu item is used to select whether the VITC
Reader will display UTC or UTC adjusted by the programmed Time
Zone Offset (Local Time). The local time will also be adjusted by the
daylight savings time adjustment if daylight savings time is in effect.
See section 3.4.8 for a discussion of daylight saving time features of
the 8010TM.
Select Vtm zone adj utc to configure the generator to output its time as
UTC.
Select Vtm zone adj loc to configure the generator to output its time as
UTC adjusted by the programmed Time Zone Offset and Daylight
saving adjustment if DST Time is On. (Local Time)