Message Block Format; Figure 4-1: Communications Protocol State Diagram - evertz 8010TM Instruction Manual

Sdi time code master
Hide thumbs Also See for 8010TM:
Table of Contents

Advertisement

R (BREAK)
R (UNDEFINED)
The communications protocol is described in Figure 4-1. The Evertz unit (Device) immediately enters
the select state upon power-up and remains there unless directed by an Enter Broadcast Cmd (02 hex)
to the broadcast communications state. The diagram shows the various states of the device. The
designation R( ) indicates the data received from the controller, while the designation T( ) indicates the
data transmitted by the Device.
4.3.

MESSAGE BLOCK FORMAT

Once communications have been established, command messages may be sent to the Device.
Each control message starts with the STX character and ends with a checksum. The message blocks
are structured as follows:
STX
SERIAL PROTOCOL
R(Enter Broadcast)
T(ACK)
SELECT
R(STX)
TIMEOUT
(10 msec)
T(NAK)

Figure 4-1: Communications Protocol State Diagram

BYTE COUNT
Revision 1.5.1
Model 8010TM SDI Time Code Master Manual
T(ACK)
R(Enter Select)
no response required
T(ACK)
T (MESSAGE)
R (MESSAGE)
MESSAGE
Broadcast
T(STX)
ERROR (Parity,checksum
undefined command, etc)
CHECKSUM
Page 4-3