Basic software procedures
5.3.20

Performing a fan test

Notes on replacing a defective fan
After replacing a defective system fan or PSU containing a defective fan,
the fan error indicators will stay lit until the next fan test. By default, a fan
test is automatically started every 24 hours. The first automatic fan test
being performed after replacing a fan will turn off the fan error indicator.
If you want to start the fan test manually, you can do so by following the
description below:
Executing the fan test via the iRMC S5 web interface
▶ Log into the iRMC S5 web interface.
The System menu is displayed on default.
▶ Open the Cooling page.
▶ Expand the Cooling Devices group.
▶ Click Start Fan Test.
For more information on iRMC settings, see the iRMC user guides.
Executing the fan test via ServerView Operations Manager
▶ Open the ServerView Operations Manager and log in.
▶ Under Administration select Server Configuration.
▶ In the hierarchy tree of the Server list tab, select the server to be
configured.
▶ In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking GO.... In the left-hand section of
the window, the Configuration tab is being activated.
▶ In the navigation area of the Configuration tab, select Other Settings.
▶ Under Daily Fan Test, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)