Fujitsu PRIMERGY RX1330 M4 Upgrade And Maintenance Manual page 348

Hide thumbs Also See for PRIMERGY RX1330 M4:
Table of Contents

Advertisement

Appendix A
Status
flashing orange
Global Error indicator (3)
See also
"iRMC-related status signals" on page
Status
off
orange on
flashing orange
HDD/SSD activity indicator (4)
Status
flashing green
Power-on indicator (5)
Status
off
green on
348
Description
CSS component failure detected.
Description
No critical event detected (non-CSS component).
Prefailure event detected (non-CSS component).
Non-CSS component failure detected.
Possible causes:
– System is out of the specified temperature range
– Defective sensor
– CPU error
– Error detected by server management software
Description
Data access in progress.
Description
The server is switched off.
– The server has been switched on but Power Cycle
Delay settings delay it from turning on for a
specified time.
– The server is switched on and operating normally.
Upgrade and Maintenance Manual
349.
RX1330 M4

Advertisement

Table of Contents
loading

Table of Contents