Fujitsu PRIMERGY RX1330 M4 Upgrade And Maintenance Manual page 149

Hide thumbs Also See for PRIMERGY RX1330 M4:
Table of Contents

Advertisement

▶ Position the HDD backplane on the three hooks (see circles).
▶ Push the HDD backplane downward. Ensure that the HDD backplane fits
into the guides (A). There are five guides, three can be seen in figure.
CAUTION
Ensure that none of the cables are strained or damaged!
Figure 68: Connecting the cables to the 3.5-inch HDD backplane
▶ Connect the following cables to the HDD backplane:
1 SAS/SATA cable, according to the length
2 SAS/SATA cable, according to the length
3 Power cable to backplane connector "X12"
4 SAS/SATA cable, according to the length
5 SAS/SATA cable, according to the length
6 SAS/SATA cable plug "P6" to backplane connector "SGIO"
7 OOB cable to backplane connector "SMBus"
For the cable plans, see
Concluding steps
▶ Insert all HDD modules, see
page
142.
Ensure that you reinstall the HDD module in the bay it was located
before the HDD backplane replacement.
"Reassembling" on page
RX1330 M4
Hard disk drive (HDD) / solid state drive (SSD)
"Appendix B" on page
"Installing a 3.5-inch HDD module" on
52.
Upgrade and Maintenance Manual
365.
149

Advertisement

Table of Contents
loading

Table of Contents