Fujitsu PRIMERGY RX1330 M4 Upgrade And Maintenance Manual page 163

Hide thumbs Also See for PRIMERGY RX1330 M4:
Table of Contents

Advertisement

7.5.6
Replacing the 4 x 2.5-inch HDD backplane (right
side) or PCIe SSD backplane
Field Replaceable Unit
(FRU)
Tools:
tool-less
Preliminary steps
"Locating the defective server" on page
"Shutting down the server" on page
"Disconnecting the power cord" on page
"Getting access to the component" on page
▶ Release all HDD/SSD modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD module" on page
CAUTION
The HDD/SSD modules need not to be removed.
If you want to remove them nevertheless, check if all HDD/SSD
modules are uniquely identified so that you can reinsert them
into their original bays.
▶ Release all dummy modules and pull them out a few centimeters, see
"Removing the 2.5-inch dummy module" on page
RX1330 M4
Hard disk drive (HDD) / solid state drive (SSD)
45.
Upgrade and Maintenance Manual
Hardware: 5 minutes
43.
46.
48.
156.
153.
163