L1
C x x x
D I A G N O S T I C
||
L2
M x x x
C x x x || V I E W
L1
M x x x ||
L2
L1
L2
L1
L2
L1
L2
L1
L2
C x x x || E N T E R
L1
M x x x ||
L2
L1
L2
L1
L2
L1
L2
L1
L2
L1
L2
C x x x || R E A D
L1
M x x x ||
L2
L1
L2
L1
L2
L1
L2
L1
L2
L1
L2
L1
L2
Form 169558
UNLOADING AND ASSEMBLY
M O D E ?
N O / Y E S
E R R O R
C O D E S ?
N O / Y E S
C x x x || V I E W
T R A C T O R
M x x x ||
N O / Y E S
1 || 1 2 3 4 . 5
4 7 || S E N S O R
E
2 || 1 2 3 4 . 5
7 1 || L O W
E
H Y D R A U L I C
C x x x || E X I T
T R A C T O R
M x x x ||
N O / Y E S
S E N S O R
N O / Y E S
C x x x || H E A D E R
M x x x ||
E N A B L E / D I S A B L E
C x x x || H E A D E R
M x x x ||
E N A B L E / D I S A B L E
C x x x || K N I F E
S P E E D
M x x x ||
E N A B L E / D I S A B L E
C x x x || R E E L
S P E E D
M x x x ||
E N A B L E / D I S A B L E
C x x x || E X I T
S E N S O R
M x x x ||
N O / Y E S
S E N S O R
I N P U T S ?
N O / Y E S
C x x x || S E N S O R
M x x x || H D R
H E I G H T
C x x x || S E N S O R
M x x x || H E A D E R
C x x x || S E N S O R
M x x x || K N I F E
S P E E D
C x x x || S E N S O R
M x x x || R E E L
S P E E D
C x x x || S E N S O R
M x x x || W H E E L
S P E E D
C x x x || E X I T
R E A D
M x x x ||
N O / Y E S
If "NO" then jump to:
T R A C T O R
S E T U P ?
E N T E R
C O D E S ?
H R S
1 2 3
V O L T S
L O W
H R S
1 2 3
O I L
C O D E S ?
S E T U P ?
R E A D
H T
S E N S O R
T I L T
S E N S O R
S E N S O R
S E N S O R
S E T U P ?
A C T I V A T E
I N P U T
3 . 5 9
V
I N P U T
A N G L E
1 . 8 4
V
I N P U T
1 2 3
H Z
I N P U T
1 2 3
H Z
I N P U T
1 2 3
H Z
S E N S O R S ?
35
If "NO" then jump to:
S E N S O R
S E T U P ?
If "NO" then jump to:
E N T E R
S E N S O R
The last 10 distinct error codes are stored along
with the code #, Exxx, engine hours and number of
occurrences. The "arrow" keys are used to cycle
between codes.
If "NO" then jump to:
V I E W
T R A C T O R
If "NO" then jump to:
S E N S O R
I N P U T S ?
The operator can select each sensor and
selectively enable or disable the sensor in the event
of a sensor malfunction.
If no expansion module or an A30 auger header is
selected, the corresponding menu items should be
suppressed.
When "SELECT" is pressed the program goes to
the EXIT SENSOR SETUP? selection.
If "NO" then jump to:
K N I F E
S P E E D
Or to the first sensor "installed"
If "NO" then jump to:
F U N C T I O N S ?
For diagnostic purposes each sensors input signal
can be read.
If no expansion module or an A30 auger header is
selected, the corresponding menu items should be
suppressed.
When "SELECT" is pressed the program goes to
the EXIT READ SENSORS? menu selection.
Adds a selection to be able to read in the wheel speed
frequency.
If "NO" then jump to:
S E N S O R
I N P U T
H D R
H E I G H T
(continued next page)
S E T U P ?
C O D E S ?
S E N S O R
3 . 5 9
V
Revision A