8.2

Drive to Increment - DRVI Instruction

8.2.1

Instruction Format

1. Instruction Format
FNC 158
D
DRIVE TO
INCREMENT
Command
input
2. Data setting
Operand type
*1.
*2.
3. Devices
Operand
type
S
1
S
2
D
1
D
2
1 : Specify Y000, Y001, or Y002
*3.
*4.
*5.
Note:
• To use an FX
special adapter.
• Differential line drive type outputs will be used for the outputs of the high-speed output special adapter.
B - 122
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
16-bit
instruction
DRVI
DRVI
9 steps
FNC158
S
S
1
2
DRVI
S
Specifies the number of output pulses (relative address).
1
Specifies the output pulse frequency.
S
2
Specifies the pulse output number.
D
1
Specifies the rotation direction signal output destination device number.
D
2
Setting range : -32,768 to +32,767 (excluding 0) for 16-bit operation
: -999,999 to +999,999 (excluding 0) for 32-bit operation
Setting range : 10 to 32,767 Hz for 16-bit operation
For 32-bit operation, however, the setting range is as shown in the following table.
FX
PLC
3U
FX
/FX
3S
3G
Bit device
System user
X
Y
M T C S D.b KnX KnY KnM KnS T C D
1
2
3
*5
Y003
from a high-speed output special adapter
Y002 is not available in FX
High-speed output special adapters can be connected only to the FX
To use Y002 and Y003 with a high-speed output special adapter, connect a second high-speed output
special adapter.
PLC of relay output type or triac output type, be sure to connect a high-speed output
3U
search engine
Instruction
Execution condition
symbol
Continuous
execution
-
type
D
D
1
2
Description
*2
Pulse output destination
High-speed output special adapter 10 to 200,000(Hz)
/FX
/FX
/FX
PLC Main unit (transistor output)
3GC
3U
3UC
Word device
Digit designation
System user
  
  
*3
transistor output from the main unit, or specify Y000, Y001, Y002
*4
.
PLC (14-point and 24-point type) and FX
3G
8 1-Speed Positioning - DRVI/DRVA Instruction
8.2 Drive to Increment - DRVI Instruction
32-bit
Instruction
instruction
symbol
DDRVI
17 steps
-
*1
Spe-
Con-
cial
Index
stant
unit
R U\G V Z Modify K
H
4
5
 
 
4
5
 
 
/FX
PLC.
3S
3GC
PLC.
3U
Execution condition
Continuous
execution
type
Data type
BIN16/32-bit
Bit
Setting range
10 to 100,000(Hz)
Others
Real
Char-
num-
acter
Pointer
ber
string
E
""
P
*5
, or

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3g seriesFx3gc seriesFx3u seriesFx3uc series

Table of Contents