Built-in Positioning Functions
3
Click on the «Positioning» tab, and then set Y000 (pulse output destination)
as follows.
Before clicking on the "Positioning" tab, click on the «Memory Capacity» tab, and then enter a check in the
"Positioning Instruction Settings" check box. After entering a check, positioning data can be set.
*1.
4
Click on the "Individual setting" button. The "Positioning Instruction
Settings" screen will appear. In this screen, click on the «Y0» tab to display
the positioning table for Y000 (pulse output destination). Set the data in the
positioning table as follows:
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Only available for FX
and FX
3U
search engine
Bias Speed [Hz]
Max. Speed [Hz]
Creep Speed [Hz]
Zero Return Speed [Hz]
Acceleration Time [ms]
Deceleration Time [ms]
Interrupt Input for DVIT Instruction
PLCs.
3UC
Setting item
Rotation Direction Signal
Head Address
Positioning Instruction
No. 1
Pulse (Pls)
Frequency (Hz)
Positioning Instruction
No. 2
Pulse (Pls)
Frequency (Hz)
Positioning Instruction
No. 3
Pulse (Pls)
Frequency (Hz)
Positioning Instruction
No. 4
Pulse (Pls)
Frequency (Hz)
12 Examples of Programs
12.4 Positioning Using Batch Setting Method
Setting item
Setting value
*1
Setting value
(drive to increment)
(drive to increment)
(drive to absolute)
(drive to absolute)
A
B
500
100,000
1000
Apx.
50,000
100
100
X000
Y004
R0
DDRVI
999,999
30,000
DDRVI
-999,999
30,000
DDRVA
500,000
100,000
DDRVA
100
100,000
B - 173