To read out and store the "Pulse" and "Frequency" changed by a display module or HMI:
1) In the "Positioning Instruction Settings" screen of the positioning parameters, check the "Positioning table
settings will not be initialized when the PLC is powered on" check box.
2) Click on the "Read" button to read out the set data ("Pulse" and "Frequency") from the connected main
unit.
This is exclusively for the positioning table number with the positioning type specified.
3) At the completion of register data reading, the data file will be stored.
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Check the box.
search engine
11 Batch Data Positioning Mode - TBL Instruction
11.4 Built-in Positioning Parameter Setting
Click the
"Read" button.
A
B
Apx.
B - 161