Built-in Positioning Functions
Setting item
"Up" button
"Down" button
"Insert Row" button Click this button to insert a line at the specified position.
"Delete Row" button Click this button to delete the selected line.
"Delete all Rows"
button
Positioning table
settings will not be
initialized when the
PLC is powered on
"Write" button
"Read" button
*1.
*2.
*3.
*4.
*5.
B - 158
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Click this button to move the cursor up by 1 line
(to select the line just above the cursor-positioned line).
Click this button to move the cursor down by 1 line
(to select the line just below the cursor-positioned line).
Click this button to delete all the data from the positioning table of the selected
pulse output destination device.
If this check box is checked, the built-in positioning data will not be initialized
when the PLC power is turned ON. Enter a check in this check box to retain
the changed data ("Pulse" and "Frequency" changed by the program, display
module, or HMI) even after power-off and to use the changed data after turning
on the power again. To use this function, set an uninterruptible power supply
type device as "Head Address".
Click this button to write 1600 points (FX
FX
) of data ("Pulses" and "Frequency" set on the positioning table using
3GC
GX Works2) starting from "Head Address" of the PLC.
Click this button to read out 1600 points (FX
FX
) of data ("Pulse" and "Frequency" set on the positioning table currently
3GC
used) from the PLC starting from Head Address. At the completion of data
reading, the data numbers will appear only if "Positioning Instruction" is set for
the data.
Y002 is not available in FX
Y003 is available only when two high-speed output special adapters are connected to the FX
To use an FX
-2HSY-ADP, set the rotation direction signal depending on the pulse output destination
3U
device as shown in the following table.
Pulse output destination device
Y000
Y001
Y002
Y003
Only available for FX
and FX
3U
Refer to the description of the selected instruction (positioning type).
Positioning Instruction
DDVIT (Interrupt positioning)
DPLSV (Variable Speed Pulse Output)
DDRVI (Drive to Increment)
DDRVA (Drive to Absolute)
search engine
Description of setting
/FX
3U
PLC (14-point and 24-point type) and FX
3G
Rotation direction signal
Y004
Y005
Y006
Y007
PLCs.
3UC
11 Batch Data Positioning Mode - TBL Instruction
11.4 Built-in Positioning Parameter Setting
) or 1200 points (FX
/
3UC
3G
/FX
) or 1200 points (FX
3U
3UC
PLC.
3GC
Refer to
Chapter 9
Chapter 10
Section 8.2
Section 8.3
Setting range
-
-
-
-
-
-
-
/
3G
-
PLC.