Built-in Positioning Functions
2. If the high-speed output special adapter (FX
Status of pulse
output method
setting switch
PLS•DIR side
FP/RP side
B - 182
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Signal
"Pulse output
destination device"
(pulse train)
"Rotation direction
output" (direction)
"Pulse output
destination device"
(Forward pulse train)
"Rotation direction
output" (Reverse
pulse train)
search engine
-2HSY-ADP) is used for positioning
3U
LED status during
execution of
positioning
instruction
Turned on and off
The pulse output operation is controlled by the
at high speed
positioning instruction.
The PLC may exhibit the following status:
1) The operation of the positioning instruction is
completed.
2) An operation error occurred during positioning.
OFF
The instruction, therefore, is not being executed.
To check the error, refer to the following section:
ON
Forward operation is in execution.
The PLC may exhibit the following status:
1) The positioning instruction turns ON, and operation
is being performed in the reverse rotation direction.
2) An operation error occurred during positioning
OFF
instruction. The instruction, therefore, is not being
executed.
To check the error, refer to the following section:
Turned on and off
Forward operation is being executed for a positioning
at high speed
instruction. Reverse pulse train is OFF.
The PLC may exhibit the following status:
1) The positioning instruction turns ON, and operation
is being performed in the reverse rotation direction.
2) An operation error occurred during positioning .
OFF
The instruction, therefore, is not being executed.
To check the error, refer to the following section:
Turned on and off
Reverse operation is being executed for a positioning
at high speed
instruction. Forward pulse train is OFF.
The PLC may exhibit the following status:
1) The positioning instruction turns ON, and operation
is being performed in the forward rotation direction.
2) An operation error occurred during positioning. The
OFF
instruction, the4refore, is not being executed.
To check the error, refer to the following section:
13 Troubleshooting
13.1 LED Indicator Lamp Check
Description
Refer to Subsection 13.2.1 "Error Code
Check Method".
Refer to Subsection 13.2.1 "Error Code
Check Method".
Refer to Subsection 13.2.1 "Error Code
Check Method".
Refer to Subsection 13.2.1 "Error Code
Check Method".