Built-in Positioning Functions
2.6

List of Functions

The instructions needed for the FX
the following table:
Positioning instruction
Mechanical zero return
DSZR
instruction
ZRN
instruction
Absolute position detection system
ABS
instruction
1-speed positioning
DRVI
instruction
DRVA
instruction
1-speed positioning with interruption
DVIT
instruction
*1
Variable speed operation
PLSV
instruction
Others
TBL
instruction
*3
B - 40
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
zero return
with DOG
search
function
Zero-point: ON
(Dog: OFF when ZRN
zero return
instruction is used)
Absolute
value detec-
tion system
(Reading of
current ABS
value)
Relative
positioning
Absolute
positioning
Start
Interruption
positioning
Start
Operation without
Acceleration/Deceleration
Variable
Start
positioning
(Variable
Operation with
Speed Pulse
Acceleration/Deceleration*
Output)
Start
No.
Positioning
1
using batch
2
setting
3
method
4
search engine
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
Operation
If the DSZR/ZRN instruction turns ON,
mechanical zero return will be started at
Creep
Zero return
the specified zero return speed. If the dog
speed
speed
sensor is turned on, the speed will be
reduced to the creep speed. If the zero-
phase signal is input, the operation will be
stopped, and the zero return will be
DOG:ON
Start
completed.
(If the ZRN instruction is used, the dog
sensor will be turned off to stop the
operation.)
If the ABS instruction turns ON, the
current motor address will be read out
from the servo amplifier.
Reads out the
current value.
If the DRVI/DRVA instruction turns ON,
Operation speed
the operation will be started at the
Transfer distance
operation speed. When the workpiece
reaches the target position, the operation
Target position
will be stopped.
Operation speed
If the DVIT instruction turns ON, the
operation will be started at the operation
Transfer
distance
speed. If the interrupt input turns ON, the
workpiece will go the specified transfer
Interrupt
distance, before decelerating to stop.
input: ON
Operation speed
If the PLSV instruction turns ON,
operation will be started at the specified
speed. With an operation speed change,
the speed changes to the specified speed,
Speed
Speed
Instruction:
change
change
OFF
and operation continues.
At PLSV instruction OFF, the pulse output
2
stops.
Operation speed
With acceleration/deceleration operation,
the PLC controls acceleration and
deceleration.
Speed
Speed
Instruction:
change
change
OFF
Position Speed Instruction
Preliminarily set the positioning points
1000
2000
DRVI
using parameters. If the TBL instruction
20000
5000
DRVA
turns ON, the workpiece will be
50
1000
DVIT
transferred to the specified point.
800
10000
DRVA
PLC built-in positioning functions are shown in
Description
2 Specifications
2.6 List of Functions
Refer to
Chapter
6.
Chapter
7.
Chapter
8.
Chapter
9.
Chapter
10.
Chapter
11.