Built-in Positioning Functions
3) For
Turning on the near-point signal will reduce the speed to the creep speed. Turning off the near-point
signal will complete the zero return operation.
• If an input X000 to X007 (X000 to X005 for FX
signal (DOG), the PLC interruption function will be used to stop the operation. (To output the CLEAR
signal, turn on the "CLEAR signal output function enable" relay.)
Under the following condition, however, operation may be affected by the input filter or the scan time of
the sequence program, and the operation, therefore, may not be stopped exactly at the origin.
- An input number of X010 or higher (or other device (auxiliary relay, etc.)) is specified.
4) For
5) Zero return direction
For this instruction, the zero return direction is set to the reverse rotation direction.
(During zero return operation, the value indicated in the current value register will be decreased.)
To perform zero return in the forward rotation direction, follow the example program below to control the
direction output.
a) Turn on Y (rotational direction signal).
b) Refresh Y output using the REF (FNC 50) instruction.
c) Execute the ZRN instruction (zero return instruction).
d) With the execution completion flag (M8029) of the ZRN instruction (zero return instruction), reset
Example program:
In the program shown below, Y004 is specified as the rotation direction signal output device for Y000.
Command
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
S
, specify the near-point signal (DOG) input device number (NO contact).
3
If an input relay X010 or higher (X006 or higher for FX
(DOG), the input filter will be applied.
D
, specify a pulse output number in the range of Y000 to Y003.
Y (rotational direction signal).
input
M12
M8029
M8329
search engine
For details, refer to "1. Zero return operation".
PLC) of the main unit is specified for the near-point
3S
For programming details, refer to Section 4.7.
To use the main unit (transistor output), refer to Section 4.8.
To use a high-speed output special adapter, refer to Section 4.9.
FNC 50
REFP
FNC156
S
S
1•
2•
DZRN
6 Mechanical Zero Return - DSZR/ZRN Instruction
6.3 Zero Return (ZRN Instruction)
PLC) is specified for the near-point signal
3S
RST
M10
RST
M11
SET
M12
Turns on (sets) Y004 as the
a)
SET
Y004
rotational direction signal of
Y000 (pulse output destination).
Refreshes Y000 to Y007.
b)
Y000
K8
c)
Executes ZRN instruction.
S
Y000
3•
Resets the rotational direction
d)
RST
Y004
signal (Y004) using the instruction
execution complete flag.
SET
M10
Origin data reading completion
flag
RST
M12
Resets the rotational direction
signal (Y004) using the
RST
Y004
instruction execution abnormal
end flag.
SET
M11
Abnormal end of zero return
RST
M12
A
B
Apx.
B - 113