Input/Output Assignment - Mitsubishi Electric FX3S Series User Manual

Hide thumbs Also See for FX3S Series:
Table of Contents

Advertisement

FX
/FX
/FX
3S
3G
3GC
Built-in Positioning Functions
12.1

Input/Output Assignment

The programs shown in this chapter use 1 axis for Y000 (pulse output destination device). If other pulse
output destination devices are used, modify corresponding device numbers shown in the table below when
referencing the description.
When the FX
appendix, and replace with those devices.
Pulse train
(pulse output destination)
Direction
(rotation direction signal)
CLEAR signal
Zero-phase signal
"Servo ready" signal
Immediate stop command
Zero return command
Jog (+) command
Jog (-) command
Forward rotation positioning
command
Reverse rotation positioning
command
Stop command
Near-point signal (DOG)
Interrupt signal
Forward rotation limit (LSF)
Reverse rotation limit (LSR)
To use absolute
position detection
system
*1.
*2.
*3.
*4.
*5.
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
PLC is used, check the input and output numbers in the connection examples of the
3S
Signal
*1
*2, *3
*3, *4
*4, *5
*6
*4, *5
*7
*7
ABS (bit0)
ABS (bit1)
"Send data ready"
signal
Servo-ON signal
"ABS data transfer
mode" signal
"ABS data
request" signal
To use the "forward rotation pulse train" signal and "reverse rotation pulse train" signal of a FX
2HSY-ADP, change the name of this signal to "forward rotation pulse train" signal when reading the
description.
To use the "forward rotation pulse train" signal and "reverse rotation pulse train" signal of a FX
2HSY-ADP, change the name of this signal to "reverse rotation pulse train" signal when reading the
description.
If an FX
PLC below Ver.2.20 is used, exchange the direction signal output number with the CLEAR
3UC
signal output number.
If the absolute position detection system is used, and if the DSZR instruction and ZRN instruction are
not used for the first zero return, this signal is not needed. To use the absolute position detection
system, refer to the following chapter and manual.
To use the ZRN instruction for zero return, assign the input number of the near-point signal (DOG) to
the zero-phase signal. This is needed since the ZRN instruction will not use the zero-phase signal.
search engine
Input/output number
Y000 Y001 Y002 Y003
Y000 Y001 Y002 Y003
Y004 Y005 Y006 Y007
Connected to MELSERVO Series
servo amplifier.
Y020 Y024 Y030 Y034
X004 X005 X006 X007
X014 X015 X016 X017
X020 X040 X050 X070
X021 X041 X051 X071
X022 X042 X052 X072
X023 X043 X053 X073
Connected to external switches.
X024 X044 X054 X074
X025 X045 X055 X075
X030 X034 X060 X064
X010 X011 X012 X013
X000 X001 X002 X003
Connected to sensors and limit switches.
X026 X046 X056 X076
X027 X047 X057 X077
X031 X035 X061 X065
X032 X036 X062 X066
X033 X037 X063 X067
Connected to MELSERVO Series servo
amplifier
Y021 Y025 Y031 Y035
(MR-J4A, MR-J3A, MR-J2SA, MR-J2A,
MR-HA)
Y022 Y026 Y032 Y036
Y023 Y027 Y033 Y037
Refer to Chapter 7 and the manual of your servo amplifier.
12 Examples of Programs
12.1 Input/Output Assignment
Connected to
-
3U
-
3U
B - 163
A
B
Apx.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3g seriesFx3gc seriesFx3u seriesFx3uc series

Table of Contents