Built-in Positioning Functions
Example program:
In the following program, the zero return instruction with DOG search function (DSZR), variable speed pulse
output (PLSV) instruction, and interrupt positioning (DVIT) instruction are used for the pulse output
destination (Y000) under the conditions shown in the following table.
1) Set conditions
Items related to speed
Maximum speed
Bias speed
Acceleration time
Deceleration time
Zero return speed
Creep speed
Items needed for DSZR instruction (zero return instruction with DOG search function)
Zero return direction
CLEAR signal output
CLEAR signal device change
Logic of near-point signal
Logic of zero-phase signal
Items needed for variable speed pulse output (PLSV) instruction
Acceleration/deceleration Operation
Items needed for interrupt positioning (DVIT) instruction
Interrupt input signal device change
User interrupt input command
Logic of interrupt input signal
Forward limit, reverse limit, and immediate stop of pulse output
Forward limit
Reverse limit
Immediate stop of pulse output
*1.
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Setting item
Only available for FX
3U
search engine
Description of setting
30000Hz
10Hz
200ms
200ms
5000Hz
500Hz
Reverse rotation direction
Output to Y010
Sets the positive logic (turning on the input will
turn on the near-point signal).
Sets the positive logic (turning on the input will
turn on the zero-phase signal).
If X012 is turned on, the variable speed pulse
output (PLSV) instruction will be activated to
accelerate or decelerate the operation.
*1
Sets X007 for interrupt inputs.
Interrupt positioning (DVIT) instruction will not
be used for the pulse output destinations
Y001, Y002, and Y003.
Do not use.
Sets the negative logic (turning off the input
will turn on the interruption signal).
If X010 is turned off (if the NC contact is
turned on), the limit switch will be activated.
If X011 is turned off (if the NC contact is
turned on), the limit switch will be activated.
Do not use.
and FX
PLCs.
3UC
4 Before Programming
4.5 Setting of Various Items on PLC Side
Related
Setting value
device
or condition
D8344,
D8343
K30000
(32-bit)
D8342
K10
D8348
K200
D8349
K200
D8347,
D8346
K5000
(32-bit)
D8345
K500
M8342
OFF
M8341
ON
M8464
ON
D8464
H0010
M8345
OFF
M8346
OFF
ON:
M8338
If X012 = ON
M8336
ON
D8336
HFFF7
M8460
-
M8347
ON
ON:
M8343
If X010 = OFF
ON:
M8344
If X011 = OFF
M8349
-
B - 69