Tandberg Data Autoloader Tandberg LTO2 Installation And User Manual page 74

Tandberg data tandberg lto2 autoloader installation and user's manual
Table of Contents

Advertisement

Error code
The
Autoloader
CMer****E0
hardware error.
CMer****E1∼
The Autoloader detected an error during
CMer****E3
the P move system initialization.
CMer****E4∼
The Autoloader detected an error during
CMer****E6
the P move system initialization.
CMer****E7∼
An error that occurred during the
CMer****E8
operation of the bar code reader.
CMer****ED∼
CMer****EF
CMer****F0∼
The Autoloader detected an error during
CMer****F9
error restoration.
CMer****FA∼
CMer****FE
The Autoloader detected timeout error
D.err 0101
on the communication with the drive.
The Autoloader detected parity error on
D.err 0110
the communication with the drive.
The Autoloader detected framing error
D.err 0111
on the communication with the drive.
The Autoloader detected overrun error
D.err 0112
on the communication with the drive.
The Autoloader detected a error on the
D.err 0140
Load/Unload command.
The Autoloader detected a error on the
D.err 0170
communication with the drive.
The Autoloader detected a error on the
D.err 0180
communication with the drive.(NAK
retry over)
The Autoloader detected a error on the
D.err 0181
communication with the drive.(SNAK
retry over)
D.err 0102∼
The
Autoloader
D.err 010F
position or timeout error before issuinig
D.err 0113∼
Load/Unload/Unthread command.
D.err 013F
The Autoloader detected timeout error
D.err 0190
before issuing Unload command.
The Autoloader detected timeout error
D.err 0191
before finishing Unload command.
The Autoloader detected state error on
D.err 0192
the communication with the drive .
Cause
detected
internal
detected
cartridge
- 58 -
Recovery Procedure
・Replace the Autoloader (not including the Drive
Sled Assembly).
・Remove the cartridge from the transporter.
・Switch off the power of the Autoloader and then
switch the power back on.
・Check whether there is any foreign matter in the
transporter.
・Switch off the power of the Autoloader and then
switch the power back on.
・Switch off the power of the Autoloader and then
switch the power back on.
・Execute cleaning of the Roller.See"Section 5.1.2"
・ If the phenomenon has a relapse,contact your
nearest Customer Support Center.
・Switch off the power of the Autoloader and then
switch the power back on.
・ If the phenomenon has a relapse,contact your
nearest Customer Support Center.