Error code
CMer****21∼
The Autoloader detected an error during
CMer****27
ejection of the cartridge from the drive.
CMer****2B
The Autoloader detected a
CMer****2C
communicating error with the drive.
CMer****2E
CMer****31∼
CMer****39
The Autoloader detected an error during
CMer****3A∼
loading of the cartridge to the drive.
CMer****3F
The Autoloader detected an error during
CMer****51∼
ejection of the cartridge from the fixed
CMer****55
slots.
The Autoloader detected an error during
CMer****5A∼
ejection of the cartridge from the
CMer****5F
magazine.
CMer****61∼
CMer****69
The Autoloader detected an error during
loading of the cartridge to the fixed
slots.
CMer****6F
The Autoloader detected an error during
CMer****71∼
loading of the cartridge to the
CMer****79
magazine (i.e. putting operation).
An error that occurred during the
CMer****B0∼
operation of the (optional) bar code
CMer****BE
reader.
CMer****C0
The Autoloader detected an error during
CMer****C1
error restoration.
CMer****D0∼
The Autoloader detected an error during
CMer****D4
the Y move system initialization.
The Autoloader detected an error during
CMer****D7∼
Initialize Element Status command
CMer****D9
execution from SCSI.
CMer****DA∼
The Autoloader detected an error during
CMer****DC
the Y move of the transporter.
Cause
- 57 -
Recovery Procedure
・Execute cleaning of the Roller.See"Section 5.1.2"
・ If the phenomenon has a relapse,contact your
nearest Customer Support Center.
・Switch off the power of the Autoloader and then
switch the power back on.
・Execute cleaning of the Roller.See"Section 5.1.2"
・ If the phenomenon has a relapse,contact your
nearest Customer Support Center.
・Check whether there is a cartridge in slot 10.
・Check whether there is any foreign matter in the
magazine or transporter.
・Switch off the power of the Autoloader and then
switch the power back on.
・Switch off the power of the Autoloader and then
switch the power back on.
・Check whether there is any foreign matter in the
transporter.
・Switch off the power of the Autoloader and then
switch the power back on.
・Check whether there is any foreign matter in the
transporter.
・Switch off the power of the Autoloader and then
switch the power back on.
・Check whether there is any foreign matter in the
transporter.
・Switch off the power of the Autoloader and then
switch the power back on.