Phenomenon
Autoloader Performance
Data backup efficiency of the
Autoloader is poor.
Operation
Cannot write to data cartridge.
Cleaning
The cleaning message is
displayed repeatedly.
Alarm LED is brinking.
"REQ CLNROL" message is
displayed repeatedlly.
Others
The cartridge remains in the
drive.
Recovery Procedure
Check whether the Autoloader drive is connected to an exclusive SCSI
device and whether it is part of a daisy chain connection with another tape
drive or hard drive.
・Check the access rights of the host device against the file system.
・Check whether the data cartridge being used is the proper type.
・Check the write protect tab of the tape and ascertain whether the tape is in
a condition that can accept writing.
・Replace with a new data cartridge.
・Replace the current cleaning cartridge with a new one.
・When a message to the effect that cleaning is required appears on the
LCD even after cleaning of the drive, replace the cleaning cartridge.
・Execute cleaning of the Roller.See"Section 5.1.2"
・Check the setting of the application software(change setting ,
removing the cartridge after backup job).
・Eject from operation panel.
・Execute cleaning of the Roller.See"Section 5.1.2"
・If the phenomenon has a relapse,contact your nearest Customer Support
Center.