P000 Lock
Secures the MultiRanger from changes.
Primary Index
Values
Related
WARNING:
Use this lock as backup security only. It uses a fixed value which can
be discovered by unauthorized personnel.
Access this parameter directly (type 000) and enter any value (except 1954) to secure
programming lock. To unlock the MultiRanger, access this parameter and enter 1954.

Quick Start (P001 to P007)

P001 Operation
Sets the type of measurement required for the application.
Primary Index
Values
Alters
7ML19981FB05
MultiRanger 100/200 – INSTRUCTION MANUAL
Global
1954
*
OFF (programming permitted)
Simulation Controls (relays energize based on simu-
-1
lated level)
other
lock activated (programming secured)
Simulation on page 85
Single Point Model
Global
0
Out-of-service
1
Level – how full the vessel is (MR 200: volume – P050)
2
Space – how empty the vessel is (MR 200: ullage – P050)
3
*
Distance – distance from transducer to material
4
DPD – dual point difference [MR 200]
5
DPA – dual point average [MR 200]
6
OCM – flow rate in an open channel [MR 200]
7
Pump Totalizer – total pumped volume [MR 200]
P600 Primary Measuring Device
Dual Point Model
Transducer