Siemens MAG 1100 Operating Instructions Manual page 85

Electromagnetic flowmeters
Table of Contents

Advertisement

SITRANS F M
Type
Enclosure rating
EMC
Design
Weight
Material
• Enclosure
- MAG 1100
• Terminal box
- Standard
- Option
• Fixing studs
• Gaskets
- Standard
- Option
• Pipe connection adapters:
DN 2, 3, 6 and 10 (
/
"
,
1
12
, ¼
and
)
/
"
"
/
"
1
3
8
8
Liner
• MAG 1100 (Ceramic)
Electrodes
• MAG 1100 (Ceramic)
• MAG 1100 (PFA)
Cable entries
Certificates and approvals
Conforms to
Custody Transfer
(MAG 5000/6000 CT)
Ex approvals
MAG 1100 (Ceramic)
• ATEX sensor
• Sensor with/without
MAG 5000/6000
MAG 1100 (PFA)
• Sensor with/without
MAG 5000/6000
1)
Conditions are also dependent on liner characteristics
For technical specifications for transmitter - please see transmitter pages.
10
2. Technical data
MAG 1100
See dimensional drawings
Stainless steel AISI 316L (1.4404)
Fibre glass reinforced polyamide (no ATEX)
Stainless steel AISI 316 (1.4436) (ATEX)
Stainless steel AISI 304 (1.4301),
Number and size to EN 1092-1:2001
EPDM (max. 150 °C, PN 40 (max. 300 °F, 600 psi))
• Graphite (max. 200 °C, PN 40 (max. 390 °F, 600 psi))
• PTFE (max. 130 °C, PN 25 (max. 270 °F, 300 psi))
• Stainless steel, AISI 316
• Hastelloy C22
• PVDF
• DN 2, 3 (
"): Zirconium oxide (ZrO
/
",
/
1
1
12
8
• DN 6 ... 100 (¼" ... 4"): Aluminium oxide Al
• Reinforced PFA (no ATEX)
• DN10 ... 100 (
" ... 4") : Platinum with gold /
/
3
8
Titanium brazing alloy
• DN 2 ... 6 (
/
" ... ¼"): Platinium
1
12
• DN 10 ... 15 (
" ... ½"): Hastelloy C276
/
3
8
• DN 25 ... 100 (1" ... 4"): Hastelloy C22
• Remote installation 2 x M20 or 2 x½ NPT
• Compact installation
- MAG 5000/MAG 6000: 4 x M20 or 4 x ½
PED – 97/23 EC and CRN (PFA)
Cold water pattern approval PTB (Germany)
Heat meter pattern approval - OIML R 75 (Denmark) Hot water pattern approval - PTB (Germany)
Hot water pattern approval - PTB (Germany)
Other media than water pattern approval -
OIML R 117 (Denmark)
ATEX 2G D sensor Ex d e ia IIB T3 - T6
FM Class 1 div 2
FM Class 1 div 2
MAG 1100 HT (High temperature)
IP67 to EN 60529 (NEMA 4X), 1 mH
89/336 EEC
See dimensional drawings
Stainless steel AISI 316L (1.4404)
Stainless steel AISI 316 (1.4436)
Stainless steel AISI 304 (1.4301),
Number and size to EN 1092-1:2001
Graphite (max. 200 °C, PN 40 (max. 390 °F, 600 psi))
)
DN 15 ... 100 (½" ... 4"): Aluminium oxide Al
2
O
2
3
Platinum with gold / Titanium brazing alloy
Remote installation 2 x M20 or 2 x ½" NPT
NPT
"
PED – 97/23 EC and CRN (PFA)
Heat meter pattern approval - OIML R 75 (Denmark)
ATEX 2G D sensor Ex d e ia IIB T3 - T6
FM Class 1 div 2
O for 30 min
2
O
2
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mag 1100 fMag 3100Mag 3100 pMag 5100 wMag 5000Mag 6000

Table of Contents