External Totalizers And Flow Samplers [Mr 200]; Relay Contacts; Totalizer - Siemens MAG 1100 Operating Instructions Manual

Electromagnetic flowmeters
Table of Contents

Advertisement

External Totalizers and Flow Samplers
[MR 200]
This feature is only available on the MultiRanger 200.
External totalizers are simple counters which count the number of relay clicks produced
by the MultiRanger. This is generally used to keep track of OCM or pumped volume totals.
Note that both of these values are also stored in the MultiRanger and are available
through communications.
Flow samplers are devices which take a sample of liquid when triggered by a relay click.
These samples are used to monitor water quality over time. Flow samplers can be driven
by OCM volume or by relay click volume settings depending on the application
requirements.

Relay Contacts

Pumped volume is calculated at the end of the pump cycle. Totalized volume given
through a relay set up for totalizer (P111[r]=40) will be given in bursts at this time.
Both the open and closed times for the relay contact are provided by P645 and are preset
to 0.2 seconds. Partial units are added to the next pump cycle.
Example:
Shows a relay set up to make one contact for every cubic metre (m

Totalizer

To set the totalizer to provide relay contact to an external counter, use the following:
1 Contact per 10
Page 70
MultiRanger 100/200 – INSTRUCTION MANUAL
P645
3
3
4m
2m
Pump Cycle
Counter Formula
P640
P640 is preset to 0 so the default number of
units
contacts for a pumped volume cycle is
equivalent to the number of volume units.
P645
3
3
2m
3m
3
) of liquid.
3
1m