P301 Temperature, Transducer Minimum
View the lowest temperature encountered, as measured by the temperature sensor in
the transducer (if applicable).
Primary Index
Values
Related
Press CLEAR
P302 Temperature, Sensor Maximum
View the highest temperature encountered, as measured by the TS-3 Temperature
Sensor (if applicable).
Primary Index
Values
Related
Press CLEAR
P303 Temperature, Sensor Minimum
Shows the lowest temperature encountered, as measured by the TS-3 Temperature
Sensor (if applicable).
Primary Index
Values
Related
Press CLEAR
7ML19981FB05
MultiRanger 100/200 – INSTRUCTION MANUAL
Transducer
Range: - 50 to 150°C (view only)
Preset: 150°C
P300 Temperature, Transducer Max
keys to reset the log after an open circuit on the transducer wiring.
Global
Range: - 50 to 150°C (view only)
Preset: - 50°C
P303 Temperature, Sensor Min
keys to reset the log after a short circuit on the transducer wiring.
Global
Range: - 50 to 150°C (view only)
Preset: 150°C
P302 Temperature, Sensor Max
keys to reset the log after an open circuit on the transducer wiring.