5 Battery Replacement

The server CMOS contains an internal lithium cell. A risk of fire and burns
exists if the battery is not properly handled. To reduce the risk of personal
injury:
DO NOT recharge the battery.
DO NOT expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose
of the battery in fire or water.
Replace only with the spare designated for this product.
After replacing the battery, you must reconfigure the server and reset
the system date and time.
To remove the battery:
1.
Power down the server and disconnect the power cables from the server.
2.
Gently slide and remove the server out of the rack.
3.
Remove the access panel (Refer to
4.
Disconnect the cable of the super-capacitor.
5.
Remove the air duct (Refer to
6.
Locate the battery on the motherboard.
7.
Gently press the clip on the battery socket until the battery pops up from the
socket. Remove the battery.
DO NOT pry or press the battery using excessive force.
Failing to remove the battery properly might damage the socket on the
motherboard.
Access Panel
Replacement).
Air Duct
Replacement).